How to change Regeneration Days Override
–
Unlock Valve
–
Press Up & Down arrow together for 5 secs until you hear
a beep.
–
Press the Menu Button.
–
Press down arrow four times.
–
H-## will be on the screen. (This is the current setting for the days
override
–
Press the Menu Button
–
The Digits will then flash change the number to desired number of days
by pressing the up or Down button & press Menu to save.
Set Water softener Capacity
–
Unlock Valve
–
Press Up & Down arrow together for 5 secs until you hear
a beep.
–
Press the Menu Button.
–
Press down arrow four.
–
An hourglass and a m³ symbol will light up
–
Press Menu Button
–
The digits will then flash, change the number to the amount of capacity
estimated for the ion exchange process in litres the softener will
produce eg:
Feed hardness
(ppm)
Total Capacity
(m³)
50ppm
34m³
70ppm
24 m³
90ppm
18.8 m³
120ppm
14.1 m³
150ppm
11.3 m³
200ppm
8.5m³
250ppm