RUNLUCKY SHOWER SOFTENER 

 

 

Cut-off 

Filter Valve 

 

Optional 

1/2

Elbow Connector 

 

 

The following installation steps for installing before water heater 

2.3.2.1.Install the cold and hot connector 
a.Shut off the source inlet water, remove the water mixing valve with a spanner, keep the original center 
distance of eccentric connector the same, as shown in Figure 10.   
b.Take out the hot water connector, cold water connector and 3/4

washers. As shown in Figure 11 to 

assemble the cold water connector and hot water connector on the eccentric connectors on the wall. 
Make sure the washers no damaged.   
c.Use spanner, connect the cold water side of water mixing valve with the cold water connector, connect 
the hot water side of water mixing valve with the hot water connector. Make sure the washers no 
damaged, as shown in Figure 12. 

 

d.Figure 13 is the schematic view of after water mixing valve installed. According to the view and mark 
on connector, adjust the outlet of cold water connector adown, as shown in Figure 13. 
e.In order to prevent the big grain substance entering into softener which will affect the effectiveness, it is 
suggested to install a shut-off filter valve. Take out shut-off filter valve and washer, tighten it between cold 
water and raw water. Place the washer as shown in Figure 14. After installation as shown in Figure 15.   

 

2.3.2.2.Pipeline Installation Instruction 
a.Install the 1/2

animated elbow connector on rear outlet behind the shower softener. Disassemble the 

sealing plug on rear outlet behind the shower softener as shown in Figure 16, take out the 1/2

animated elbow connector from the accessories bag, tighten it on rear outlet as shown in Figure 17. 
Place the washer, schematic view of after installation as shown in Figure 18. 
b.Choose the appropriate location to hang the shower softener on the wall.(Please refer the previous 
product installation instructions) 

Summary of Contents for RL-R50/MYA-1

Page 1: ...mainly used for making soft water for shower can also be used in applications such as floor heating beauty salon hairdressing salon washing machines etc The treated water of the product can not be dru...

Page 2: ...ater 4 2 3 2 Installed before Water Heater 5 2 3 3 Drain Pipeline Installation 8 2 3 4 Power Cable Installation 8 3 Trial Running 8 4 Regeneration Operation 9 4 1 Water Treatment Capacity 9 4 2 Regene...

Page 3: ...y 5 The product is suit for municipal tap water water pressure is 0 1 0 6 MPa water temperature is 5 70 It is forbidden to use it out of the range 6 The product is only suitable for indoor installatio...

Page 4: ...to maintain and replace the resin There is a check valve on outlet to prevent the water in water heater backflow Data saved after power off 1 2 Technical Parameters Item Requirement Working Pressure...

Page 5: ...n and pipeline connection relate to installation type please refer the pipeline installation instruction in details When the resin goes invalid during the usage of the product it needs to add salt Dep...

Page 6: ...xing valve with adjustable spanner as shown in Figure 4 2 3 1 2 Tighten the nut of sprinkler on the outlet of shower softener as shown in Figure 5 2 3 1 3 Connect the outlet of water mixing valve with...

Page 7: ...ener as shown in Figure 8 and 9 2 3 2 Installed before Water Heater A Installation for electrical water heater solar water heater with double pipelines for water flowing up and down as well as some si...

Page 8: ...schematic view of after water mixing valve installed According to the view and mark on connector adjust the outlet of cold water connector adown as shown in Figure 13 e In order to prevent the big gra...

Page 9: ...f water mixing valve As the product doesn t have water flow out in regeneration process a spare outlet is reserved when distribute the pipelines if needs to use water These are common installation sch...

Page 10: ...supply far away from the water mist when the machine is installed The plug of power cable uses the seal design When installation please tighten the connection nut installation as Figure 23 3 Trial Run...

Page 11: ...with salt Operation methods 4 3 1 The shower softener needs water supplied for regeneration For the shower softener installed after water heater the ender user needs to open the water mixing valve to...

Page 12: ...ross screwdriver b Take out the front cover of shower softener Be sure not scratch the surface c Unscrew 4 bolts which are used to fix resin tank to back cover by a cross screwdriver d Take out the re...

Page 13: ...RUNLUCKY SHOWER SOFTENER 11 2 If the riser pipe falls out it needs to be cleaned and inserted into resin tank 3 Be sure the drain line flow control is undamaged when installing the drain pipeline...

Page 14: ...and after water heater It has difference processes accordingly Resin invalid warning has time clock type and meter type Currently it only has time clock type The meter type will be developed later Th...

Page 15: ...e Code Meaning Explaination Code Meaning Explaination Service Service Days Fast Rinse Water flows out from drain Backwash Water flows out from drain Salt Disslution Salt Disslution Fast Rinse Water fl...

Page 16: ...It couldn t be retrieved if lost It couldn t be repaired free of charge under the below conditions 1 Guarantee period expired One year 2 Damage resulting from using maintenance and keeping that are n...

Reviews: