background image

RUNLUCKY SHOWER SOFTENER 

 

 

1. Product Overview 

1.1. Characteristics     

Wall-mounted, no brine tank, small volume. 

Dynamic regeneration mode, bigger water treatment capacity, save salt and water. 

Extensive applicability: could be installed before or after the water heater. Installed before water heater 

could prevent it damaged because of scaling.   

Automatically  controlling  the  regeneration  time,  one  button  to  realize  regeneration.  No  need  people 

stand by, LED display each status. 

Remind the use days and show the next regeneration time. 

It  has  an  automatic  backwash  function  to  reduce  the  phenomenon  of  resin  harden  and  strainer 

blockage, and improve the service lifetime of resin. 

Internal structure adopts quick connection, more easier to maintain and replace the resin. 

There is a check valve on outlet to prevent the water in water heater backflow. 

Data saved after power off. 

1.2. Technical Parameters 

Item 

Requirement 

Working Pressure 

0.1

0.6MPa 

Inlet Water Temperature 

5

℃~

70

 

Environment Temperature 

5

℃~

50

 

Electrical Facility 

AC100

240V/50

60Hz 

Water Treatment Capacity 

750L 

Inlet/Outlet 

G1/2 

Salt Consumption of Regeneration 

400g 

Applicable Water 

Municipal Tap Water 

Outlet water quality: Meet the requirement of Sanitary Safety and Function Evaluation 
Regulation of Water Treatment Device for Drink Water-General Water Treatment Device (2001). 
All the parameters of the product is tested under the standard test condition (Tested water hardness is 
CaCO3, 200 mg/ L) . The parameters will be different if the actual usage condition changed.   

1.3. Water Technological Process 

Municipal tap water                  Na cation resin         

  Soft water 

1.4. Appearance Dimensions 

     

 

1.5. Structure Chart 

Summary of Contents for RL-R50/MYA-1

Page 1: ...mainly used for making soft water for shower can also be used in applications such as floor heating beauty salon hairdressing salon washing machines etc The treated water of the product can not be dru...

Page 2: ...ater 4 2 3 2 Installed before Water Heater 5 2 3 3 Drain Pipeline Installation 8 2 3 4 Power Cable Installation 8 3 Trial Running 8 4 Regeneration Operation 9 4 1 Water Treatment Capacity 9 4 2 Regene...

Page 3: ...y 5 The product is suit for municipal tap water water pressure is 0 1 0 6 MPa water temperature is 5 70 It is forbidden to use it out of the range 6 The product is only suitable for indoor installatio...

Page 4: ...to maintain and replace the resin There is a check valve on outlet to prevent the water in water heater backflow Data saved after power off 1 2 Technical Parameters Item Requirement Working Pressure...

Page 5: ...n and pipeline connection relate to installation type please refer the pipeline installation instruction in details When the resin goes invalid during the usage of the product it needs to add salt Dep...

Page 6: ...xing valve with adjustable spanner as shown in Figure 4 2 3 1 2 Tighten the nut of sprinkler on the outlet of shower softener as shown in Figure 5 2 3 1 3 Connect the outlet of water mixing valve with...

Page 7: ...ener as shown in Figure 8 and 9 2 3 2 Installed before Water Heater A Installation for electrical water heater solar water heater with double pipelines for water flowing up and down as well as some si...

Page 8: ...schematic view of after water mixing valve installed According to the view and mark on connector adjust the outlet of cold water connector adown as shown in Figure 13 e In order to prevent the big gra...

Page 9: ...f water mixing valve As the product doesn t have water flow out in regeneration process a spare outlet is reserved when distribute the pipelines if needs to use water These are common installation sch...

Page 10: ...supply far away from the water mist when the machine is installed The plug of power cable uses the seal design When installation please tighten the connection nut installation as Figure 23 3 Trial Run...

Page 11: ...with salt Operation methods 4 3 1 The shower softener needs water supplied for regeneration For the shower softener installed after water heater the ender user needs to open the water mixing valve to...

Page 12: ...ross screwdriver b Take out the front cover of shower softener Be sure not scratch the surface c Unscrew 4 bolts which are used to fix resin tank to back cover by a cross screwdriver d Take out the re...

Page 13: ...RUNLUCKY SHOWER SOFTENER 11 2 If the riser pipe falls out it needs to be cleaned and inserted into resin tank 3 Be sure the drain line flow control is undamaged when installing the drain pipeline...

Page 14: ...and after water heater It has difference processes accordingly Resin invalid warning has time clock type and meter type Currently it only has time clock type The meter type will be developed later Th...

Page 15: ...e Code Meaning Explaination Code Meaning Explaination Service Service Days Fast Rinse Water flows out from drain Backwash Water flows out from drain Salt Disslution Salt Disslution Fast Rinse Water fl...

Page 16: ...It couldn t be retrieved if lost It couldn t be repaired free of charge under the below conditions 1 Guarantee period expired One year 2 Damage resulting from using maintenance and keeping that are n...

Reviews: