background image

 

 

V-03260

030-000 

CAB-V.24DTE/POS26-DB25M/3M 

V.24DTE cable 

V-03260

031-000 

CAB-V.24DCE/POS26-DB25F/3M 

V.24DCE cable 

V-03260

034-000 

CAB-Rolled/RJ45M-RJ45M/3m 

Rollover cable 

V-03260

060-000 

ADAPTER/RJ45F-DB9F 

RJ-45 (crystal jack)-DB9 

female converter 

V-03260

061-000 

ADAPTER/RJ45F-DB25M 

RJ-45 (crystal jack)-DB25 

male converter 

V-03260

062-000 

ADAPTER/RJ45F-DB25F 

RJ-45 (crystal jack)-DB25 

female converter 

V-03260

035-000 

CAB-E1 

UNBALANCED/DB9M-2*BNC/75 OHM/3M 

Non-balanced cable 

V-03260

037-000 

CAB-E1 

BALANCED/DB9M-RJ45M/120 OHM/3M 

Balanced cable (crystal jack) 

V-03260

036-000 

CAB-E1 BALANCED/DB9M-RJ45F/120 

OHM/3M 

Balanced cable (crystal 

connector) 

V-03400

064-100 

RG-ANT-2G3G4G0M 

2G/3G/4G full-band rod 

antenna 

V-03400

042-110 

SL10653G-2M 

Magnetic 7-mode full-band 

omnidirectional 4G antenna 

extender, 2m feeder line. 

 

7  Appendix A Switch Lightning Protection 

Installing AC Power Arrester (lightning protection cable row) 

The external lightning protection cable row shall be used on the AC power port to prevent the switch from being 

struck by lightning when the AC power cable is introduced from the outdoor and directly connected to the power port 

of the switch. The lightning protection cable row is fixed on the cabinet, operating table or the wall in the machine 

room using the line buttons and screws. 

Figure C-1 Schematic Diagram for the Power Arrester 

 

Summary of Contents for RG-RSR20-X-28 Series

Page 1: ...RG RSR20 X 28 Series Routers Hardware Installation and Reference Guide 1 0...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...site https www ruijienetworks com Technical Support Website https ruijienetworks com support Case Portal http caseportal ruijienetworks com Community http community ruijienetworks com Technical Suppor...

Page 4: ......

Page 5: ...patented technologies REF Ruijie Express Forwarding VCPU virtual CPU and X Flow All these leading technologies guarantee stable forwarding even when multiple services are enabled on the Router Becaus...

Page 6: ...t hot swappable Slot 4 and Slot 5 support DHSIC modules Hot swapping is supported Technical Specifications Table 1 2 Technical Specifications of the RSR20 X 28 Series Router Model RSR20 X 28 Interface...

Page 7: ...Various backup modes are available for high reliability requirements Compatibility The router is fully compatible with devices from other vendors Power supply By using high quality standard power sup...

Page 8: ...the RSR20 X 28 Router LED Panel Identification State Meaning System status LED SYS Off The router is not receiving power or the router is reeving power but the system fails Solid green The system is...

Page 9: ...ng data Solid green The port is connected at 1 000Mbps Blinking green The port is connected at 1 000Mbps and is exchanging data GE copper port status 1 24 Off The port is NOT connected Solid yellow Th...

Page 10: ...X 28 series router provides one Console AUX combo port Table 1 4 Specifications of the Console AUX Combo Port Index Parameter Interface Standard EIA TIA RS232 Connector RJ 45 Rate Supports 9 600bps 57...

Page 11: ...h straight through and crossover cables can be used RSR20 X 28 supports MDI MDI X Considering that you may customize cables the following section describes how to wire straight through and crossover c...

Page 12: ...nterface C When 1000BASE T interfaces are in use connect all four pairs of pins The pin connection rule is shown in Table 1 7 Table 1 7 1000BASE T Connection Table 1 8 100BASE TX 10BASE T Pin Assignme...

Page 13: ...T LED indicators see the LED Indicators section Features The fiber port uses a Small Form Factor Pluggable SFP module SFP ports The SFP ports support the following SFP modules you can select according...

Page 14: ...2 Optional Transmission Media and Transmission Distances Media Wavelength Fiber Maximum Transmission Distance 100BASE FX 1 310nm 9 125um single mode optical fiber 2 km 15 km 1000BASE SX 850nm 62 5 125...

Page 15: ...Configuring Reliability chapter in the related software configuration guide For the avoidance of system abnormality hot swapping is not allowed unless the command for unplugging the USB is entered The...

Page 16: ...C card Kingston 4GB class_4 Hot Swapping Supported The hot swapping for the SD device must strictly follow the Configuring Reliability chapter in the related software configuration guide For the avoid...

Page 17: ...n files the system scans for a USB flash drive If neither the inserted SD card nor the USB flash drive contains applicable installation packages or configuration files the software versions and config...

Page 18: ...describes basic features of high speed synchronous serial interface HS Table 1 16 Specifications of the SIC 1HS Module Protocol V 24 and V 35 are supported with cable automatic identification Rate Th...

Page 19: ...d of this cable is the DB25 male connector and the other end is the DB26 male connector Figure 1 10 V 24 DTE Cable V 24 DCE One end of this cable is the DB25 female connector and the other end is the...

Page 20: ...onnectors Figure 1 14 V 35 DTE V 35 DCE Cable The cables are customer supplied All types of HSIC 2HS cables connect to the router through the DB26 interface Choose connectors of the right type when pu...

Page 21: ...on is complete and the module is operational Port 0 1 status LED Link ACT Off The port is not connected Blinking green The port is connected properly and is transceiving data Solid green The port is p...

Page 22: ...the RJ 45 Plug One end is the DB9 male connector and the other end is the RJ 45 plug The characteristic impedance of the cable is 120 Figure 1 16 Balanced Cable with the RJ 45 Plug Considering that yo...

Page 23: ...M RJ 45 Jack Signal 1 2 RX Ring 2 1 RX Tip 4 4 TX Tip 5 5 TX Ring Non balanced cable One end is the DB9 male connector and the other end is attached with two male BNC connectors The characteristic imp...

Page 24: ...Indicates NO 4G service Solid green Indicates effective 4G service 3G service LED 3G Off Indicates NO 3G service Solid Indicates effective 3G service Received signal strength indication LED RSSI Off...

Page 25: ...40 C to 70 C 40 F to 158 F Humidity Operating humidity 5 to 95 RH EMC EMI GB 9254 2008Class A EMS GB T 17618 1998 Antenna and Installation One HSIC 4G LTE module requires 2 antennas Antennas are purc...

Page 26: ...AC Voltage Range 100VAC to 240VAC 50 60Hz Max AC Voltage Range 90VAC to 264VAC 50 60Hz Max Output Power 60W Hot Swapping Supported Redundancy Support Active Backup power redundancy Over Voltage Prote...

Page 27: ...Telnet Supporting Dynamic Host Configuration Protocol DHCP Server DHCP Client DHCP Relay and Trivial File Transfer Protocol TFTP Supporting backup Virtual Router Redundancy Protocol VRPP with high re...

Page 28: ...oint to Point Protocol PPP supporting callback and enhancing security Providing level based password check and security logs Implementing dynamic routing protocol password key authentication in OSPF a...

Page 29: ...eaters in network connection and affect the operation of the whole network The following are recommended during the installation and use of a router Keep the router dry Place the router away from heat...

Page 30: ...he ambient temperature and humidity refer to the values measured at the place 1 5m above the floor and 0 4m in the front of the router rack without protective boards The temperature and humidity requi...

Page 31: ...the board directly with hands when observing or carrying the detached circuit board 2 2 4 System Grounding Requirements A good grounding system is the basis for the stable and reliable operation of th...

Page 32: ...lowing measures must be taken to prevent lightning Ensure good contact between the grounding cable of the router and the ground Ensure that the neutral point of the AC power socket is in good contact...

Page 33: ...he Ethernet cables and module interface cables are customer supplied Related devices include HUB or switch CSU DSU or other DCE device Configuration terminal that can be a terminal or a PC installed w...

Page 34: ...ocation which occurs after the installation preparation is complete Routers are usually mounted In the cabinet On the workbench 3 2 1 Mounting on the Cabinet The Ruijie Networks RSR series router is d...

Page 35: ...sunk screw and fixing accessories Sufficient space 1U as recommended should be reserved above and beneath the router The following figures show how to install an RSR20 X 28 on a rack Figure 3 1 Brack...

Page 36: ...o the small hole at the bottom of the router and a space of 10 cm is set aside around the router for dissipation No weight is placed on the top of the router 3 3 Installing the Grounding Cable and the...

Page 37: ...cable to the socket on the rear panel of the cabinet and the other end to the AC power socket 6 Switch the router to power on position 7 For the RSR20 X 28 series router verify that the PWR indicator...

Page 38: ...rd buckle is provided by Ruijie 3 3 3 Removing the Power Cable The following table describes the procedure for removing the power cable 1 Switch off the power supply module 2 Loosen the power cord buc...

Page 39: ...porting hot swapping you have to turn off the router before plugging the modules At Step 2 and Step 3 operate gently A service module should be inserted gently and smoothly If you find it difficult to...

Page 40: ...modules to see if the module is working properly In privileged EXEC mode view interface information Check whether each service module has accepted configuration and is operational 3 6 Installing and R...

Page 41: ...difficult to push the module do not adopt forcible measures Instead unplug the module and check if the module has been aligned with the edge of the opening on the rear panel at the base of the router...

Page 42: ...of a terminal If a PC is used you must run the terminal simulation program for example Windows HyperTerminal The following describes the procedure with the HyperTerminal as example Run the HyperTermin...

Page 43: ...Process When the router is started for the first time the following information is displayed Wait for Ctrl S Master boot is ok jump to 00000000BFD30000 System bootstrap Boot Version RGOS 10 4 3b66 Rel...

Page 44: ...stalled in flash Feb 12 23 01 59 DEVICE 5 CHANGED Device RSR20 X 28 1 changed state to up Feb 12 23 02 10 HOTPLUG 5 INSTALL_OK Install service module in slot 2 OK Feb 12 23 02 10 HOTPLUG 5 INSTALL_OK...

Page 45: ...ntact the local distributor or technical support personnel 5 2 System Troubleshooting After the router is powered up the terminal will show the startup messages described in the previous chapter if th...

Page 46: ...cables V 24 Modem V 24 DCE mode V 24 DCE cables Device working in V 24 DTE mode V 35 Mode The synchronous interface of the router service module working in V 35DTE mode is connected to the peer as GV...

Page 47: ...rough cable 6 1 3 Connecting the Console Interface The console interface of a switch router is generally an RJ 45 connector that connects RJ 45 cables through DB9F or connects to the DB9M serial port...

Page 48: ...B E1 BALANCED DB9M RJ45F 120 OHM 3M Balanced cable crystal connector V 03400 064 100 RG ANT 2G3G4G0M 2G 3G 4G full band rod antenna V 03400 042 110 SL10653G 2M Magnetic 7 mode full band omnidirectiona...

Page 49: ...e LED is Red if the N line is on the left and the L line is on the right the arrester PE terminal is not grounded if the L line is on the left and the N line is on the right the polarity of the arrest...

Page 50: ...connected to the end of OUT and observe whether the LED on the borad is normal or not 5 Use the nylon button to bundle the power cables Figure C 2 Schematic Diagram for the Ethernet port Arrester Inst...

Page 51: ...munication or flat cable should be 5 times the overall diameter of the cable If the cable is constantly bent plugged or unplugged the bend radius should be 7 times the overall diameter The minimum ben...

Page 52: ...l rounded surfaces or be protected with insulating bushings Use proper cable ties to bind cables together Do not tie two or more cable ties to bind cables Cut off excess cable tie cleanly with no shar...

Page 53: ...ress on the cable When moving parts are in place ensure the excess cable length shall not contact heat sources sharp corners or edges If heat sources are unavoidable use high temperature cables instea...

Page 54: ...arms Otherwise the machine room should be located on the windward side of the pollution source perennially The previous livestock house or fertilizer warehouse cannot be used as the machine room The m...

Page 55: ...Pay attention to the location of the air conditioner Keep the air conditioner from blowing wind straight toward the device or blowing water drops from the window or air vent toward the device...

Reviews: