Figure 1-20 RG-PA60
Indicator
Table 1-23 LED Indicators on the RG-PA60 Module
LED
Panel Identification
State
Meaning
Module status LED
RDY
Off
The module is faulty.
Solid green
The module is operational.
Features
Table 1-24 Specifications of the RG-PA60 Module
Model
RG-PA60
Rated AC Voltage Range
100VAC to 240VAC, 50-60Hz
Max AC Voltage Range
90VAC to 264VAC, 50-60Hz
Max Output Power
60W
Hot Swapping
Supported
Redundancy
Support Active-Backup power redundancy
Over-Voltage Protection
Supported
Over-Current Protection
Supported
Power Cord
10A power cord
Dimensions
(W x D x H)
98.2mm x 41mm x 176mm (connector excluded)
Operating Temperature
0°C to 45°C (32°F to 113°F)
Storage Temperature
-40°C to 70°C (-40°F to 158°F)
Operating Humidity
5% to 95% RH (non-condensing)