Hardware Installation and Reference Guide Installing the Access Point
Figure 3-3 Mounting the AP on the Bracket
The AP can be installed in any of four directions on the mounting bracket depending on how you route the Ethernet
cable.
The square feet should fit easily into the mounting slots. Do not forcibly push the AP into the slots.
After installation, verify that the AP is securely fastened.
Wall Mount
1. Drill four 6 mm (0.24 in.) diameter holes in the wall and 53 mm (2.09 in.) apart, with the arrow on the mounting bracket
facing up. Tap wall anchors into the holes, and drive screws through the mounting bracket into the anchors to secure
the bracket, as shown in Figure 3-4.
Figure 3-4 Attaching the Mounting Bracket to the Wall
2.
Align the square feet on the rear of the AP with the mounting holes on the bracket, as shown in Figure 3-5.
Figure 3-5 Aligning the Square Feet with the Mounting Holes
Install the Ethernet cables before mounting the AP on the bracket.