Weight 

5.8 kg (with package) 

 

The RG-S2910C-XS-P series switch is a class A product. In a domestic environment, this product may cause 

radio interference in which case the user may be required to take adequate measures. 

Product Appearance 

The front panel of the RG-S2910C-24GT2XS-HP-E Ethernet switch provides twenty-four 10/100/1000Base-T Ethernet 

ports, two GE SFP fiber/copper combo ports, two 10G SFP+ fiber ports and one Console port. The back panel provides 

two power module slots and two expansion module slots. Figure 1-1 shows the appearance of 

RG-S2910C-24GT2XS-HP-E. 

Figure 1-1 Appearance of RG-S2910C-24GT2XS-HP-E 

 

Front Panel 

Figure 1-2 Front Panel of RG-S2910C-24GT2XS-HP-E 

 

 

Summary of Contents for RG-S2910C-24GT2XS-HP-E

Page 1: ...RG S2910C XS P Series Switch Hardware Installation and Reference Guide V1 00...

Page 2: ...n consent of Ruijie Networks is prohibited are registered trademarks of Ruijie Networks Counterfeit is strictly prohibited Exemption statement This document is provided as is The contents of this docu...

Page 3: ...Customer services hotline 86 4008 111 000 BBS http support ruijie com cn Customer services email service ruijie com cn Related Documents Documents Description Configuration Guide Describes network pro...

Page 4: ...irements of different media in network constructions RG S2910C XS P is available in 3 models Table 1 1 Models of RG 2910C XS P Model SFP 10 100 1000Base T Auto Sensing Ethernet Port 1000Base X SFP Por...

Page 5: ...10G BASE LR 10G BASE ER 1000Base T Mini GBIC GT The supported module type may change at any time Contact Ruijie Networks for details Expansion Module M2910 01XT M2910 01XS SFP Port 100Base X 1000Base...

Page 6: ...72 V Rated current 16 5 A PoE Supported on all RJ45 ports Up to 30 W power supported on each port which is determined by the actual power Power Consumption 24 port PoE 850 W Temperature Operating temp...

Page 7: ...front panel of the RG S2910C 24GT2XS HP E Ethernet switch provides twenty four 10 100 1000Base T Ethernet ports two GE SFP fiber copper combo ports two 10G SFP fiber ports and one Console port The bac...

Page 8: ...ful mode switch press the PoE Mode Switch Over button for 2 seconds or longer Back Panel Figure 1 3 Back Panel of RG S2910C 24GT2XS HP E Note Expansion module 1 slot Expansion module 2 slot Power modu...

Page 9: ...4 V 60 V to 57 V 12 V 13 4 V to 16 V Over Current Protection 54V 8 A to 10 A 12V 12 A to 16 A Over Temperature Protection Supported Load Balanced Power Supply Supported Power Supply Mix Supported with...

Page 10: ...4 A Over Temperature Protection Supported Load Balanced Power Supply Supported Power Supply Mix Supported with RG M5000E AC500P Power Cord PD650I DC Dimensions W x D x H 224 5 mm x 90 mm x 43 2 mm wit...

Page 11: ...Power Supply Supported Power Supply Mix Not supported Power Chord 10 A Dimensions W x D x H 301 mm x 90 mm x 40 mm with connecting fingers and handles 281 mm x 90 mm x 40 mm without connecting finger...

Page 12: ...binet to allow air circulation It is recommended to clean the device once every 3 months to avoid dust from blocking vents Figure 1 4 shows the flow scheme of heat dissipation Figure 1 4 Flow Scheme o...

Page 13: ...h is abnormal Power module status LED PWR1 PWR2 Solid green The power supply is operational Solid green Indicates the switching state PoE status LED PoE Solid yellow Indicates the PoE state Off The po...

Page 14: ...ffic at 100 Mbps Off The port is not connected Solid green The port is connected SFP port status LED 25F 26F Blinking green The port is receiving or transmitting traffic at 1000 Mbps RG S2910C 48GT2XS...

Page 15: ...Mini GBIC GT The supported module type may change at any time Contact Ruijie Networks for details Expansion Module M2910 01XT M2910 01XS SFP Port 100Base X 1000Base X SFP Port See Appendix C RPS Type...

Page 16: ...ported on all RJ45 ports Up to 30 W power supported on each port which is determined by the actual power Power Consumption 48 port PoE 1700 W Temperature Operating temperature 0 to 50 C Storage temper...

Page 17: ...he RG S2910C 48GT2XS HP E Ethernet switch provides forty eight 10 100 1000Base T Ethernet ports two GE SFP fiber copper combo ports two 10G SFP fiber ports and one Console port The back panel provides...

Page 18: ...specification see the section of Power Supply for RG S2910C 24GT2XS HP E Dual power input The switch can be powered by one power module or by two power modules When both two modules are available the...

Page 19: ...Meaning Off The switch is not receiving power Blinking green Initialization in progress Continuous blinking indicates errors Solid green The switch is operational System status LED Status Solid yello...

Page 20: ...Indicates the switching state PoE status LED PoE Solid yellow Indicates the PoE state Off The port is not connected Solid green The port is connected at 1000 Mbps Blinking green The port is receiving...

Page 21: ...orts M2910 01XS 2XS provides 1 2 port 10G SFP ports and supports 10GBASE SR LR LRM modes Multiple Ruijie optical modules are available for different transmission distances Applied to RG S2910C series...

Page 22: ...ack Before moving the device turn off all power supplies and dismantle all power modules Electricity Observe local regulations and specifications when performing electric operations Relevant operators...

Page 23: ...damage to your eyes Installation Site Requirements The RG 2910C XS P must be used indoors To ensure the normal working and a prolonged durable life of the equipment the installation site must meet the...

Page 24: ...g of the equipment The indoor dust falling on the equipment may be adhered by the static electricity causing bad contact of the metallic joint Such electrostatic adherence may occur more easily when t...

Page 25: ...system to prevent the interference from the electric grid The working ground of the switch should be preferably separated and kept as far as possible from the grounding device of the power equipment...

Page 26: ...installation and maintenance personnel must check whether the A C socket is well connected to the protection location of the building if not they should use a protective grounding wire to connect the...

Page 27: ...or the equipment room s wall through line buckles and screws In applications the AC first enters the lightning line bank and then the switch The lightning line banks are not provided and should be pu...

Page 28: ...Special Tools Anti static tools Meters Multimeter The RG 2910C XS P switches are not provided with a tool kit Please prepare tools on your own...

Page 29: ...nstallation Flowchart Confirmations before Installation Before installation please confirm the following points Whether sufficient airflow is available for the switch Whether the requirements of the s...

Page 30: ...essary electromagnetic shielding should be adopted For example use interface cables to shield cables Interface cables should be laid inside the equipment room Outdoor cabling is prohibited avoiding da...

Page 31: ...gure 3 3 Figure 0 3 Mounting the Switch on the Wall The RG 2910C XS P series switch can be mounted on the wall as shown in the following figure Attach the mounting brackets to the switch with the supp...

Page 32: ...n the wall as shown in Figure 3 5 Figure 0 4 Attaching the switch on the Wall Mounting the Switch on a Table Attach the four rubber feet to the recessed areas on the bottom of the switch as shown in F...

Page 33: ...ly so as to avoid any personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly connected C...

Page 34: ...o the serial port of the PC Connect one end of the console cable RJ45 to the console port of the switch Setting Terminal Parameters Step 1 Start the PC and run the terminal simulation program on the P...

Page 35: ...hoose the serial port used currently in the column use when connecting Figure 4 3 4 After choosing the serial port click OK to display the serial port parameter setting page set the baud rate to 9600...

Page 36: ...rement of the switch The console cable is correctly connected the terminal can be a PC used for configuration is already started the parameters are already configured Checking after Power on Recommend...

Page 37: ...s Solution Forgetting the management interface login password Please contact Ruijie Networks Customer Service Department for technical support The status indicator is not on after the switch is The po...

Page 38: ...ftware to be the one connected to the switch Check that the parameter configuration of the serial port matches that specified in the instructions The RJ45 port is not in connectivity or it is erroneou...

Page 39: ...le again The RPS power indicator is not on The RPS power module in use is not of the specified type The RPS power supply module is faulty The RPS power supply cable is in loose contact Replace the RPS...

Page 40: ...four pairs of wires for transmission all of which must be connected 0 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Schematic Diagram for the Four Twisted Pairs of...

Page 41: ...T 2 Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is...

Page 42: ...m Cabling Distance Intensity of Transmitted Light dBm Intensity of Received Light dBm Standards FE SFP LX MM13 10 1310 MMF 62 5 125 2km 14 14 FE SFP LH15 SM 1310 1310 SMF 9 125 15km 8 8 Mini GBIC SX 8...

Page 43: ...I FE SFP LX20 SM1550 BIDI 100M 40km FE SFP LH40 SM1310 BIDI FE SFP LH40 SM1550 BIDI 1000M 20km GE SFP LX20 SM1310 BIDI GE SFP LX20 SM1550 BIDI 1000M 40km GE SFP LH40 SM1310 BIDI GE SFP LH40 SM1550 BID...

Page 44: ...e m Modular Bandwidth MHz km Maximum Cabling distance Min Max Min Max 200 33m 62 5 160 26m 2000 300m 500 82m XG SFP SR MM850 850 MMF LC interface 50 400 66m 5 1 7 5 0 5 XG SFP LR SM1310 1310 SMF LC in...

Page 45: ...M Yes No XG SFP CU1M Passive SFP 1 28 10 3125 No XG SFP CU3M Passive SFP 3 28 10 3125 No Note electrostatic discharge ESD prevention and protection while using the SFP copper cable Please keep the bev...

Page 46: ...as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet t...