Installing the RG-2910C-XS-P
Precautions
During installation, note the following points:
Connect the power cables of different colors to the corresponding grounding posts.
Ensure that the connected power cables have sound contact.
Do not place heavy items on the switch.
Reserve a spacing of at least 10 cm around the chassis for good ventilation. Do not stack the devices.
The switch should be located at places free from the large power radio launch pad, radar launch pad, and high-frequency
large-current devices. If necessary, electromagnetic shielding should be adopted. For example, use interface cables to shield
cables.
Interface cables should be laid inside the equipment room. Outdoor cabling is prohibited, avoiding damages to device signal
interfaces caused by over-voltage or over-current of lightning.
Mounting the Switch to a Standard 19-inch Rack
The RG-2910C-XS-P switches follow the EIA standard dimensions and can be installed in 19-inch distribution cabinets.
Attach the mounting brackets to the switch with the supplied screws, as shown in Figure 3-1.
Figure 0-1 Attaching the Mounting Bracket to the Switch
Align the mounting holes in the mounting bracket with the mounting holes in the rack, as shown in Figure 3-2.
Figure 0-2