Fan 

Precaution: 

 

RG-S12010 and RG-S12006 should use standard fans for heat dissipation. 

Power Supply 

Specification: 

RG-S12010 can use the following power supplies: 

 

AC power parameters 

Model 

RG-PA1200I RG-PA2000I 

Rated voltage 

100-120V~, 200-240V~; 50/60Hz 

100-120V~, 200-240V~; 
50/60Hz 

Maximum 
voltage 

90-264V~, 47-63Hz 

90-264V~, 47-63Hz 

Maximum 
output power 

90-176V~ Power:530W 
176-264V~ Power:1400W 

90-176V~ Power:1080W 
176-264V~ Power:2000W 

Power cable 

16A 16A 

 

Precaution: 

 

When an AC power module is used, pay attention to the input voltage range. The maximum 

output power of the RG-PA1200I is different from that of RG-PA2000I in condition that the two 

modules are used for different voltage. 

 

The AC power modules are hot swappable. 

  When the AC power module is powered on, the Input and Output LEDs on the panel are 

green. 

 

To prevent damage to parts caused by rapid power cycle, do not power on RG-S12000 within 

30 seconds after power off. 

 

Use the corresponding cables to connect power modules. 

 

The dust in the air may block the air outlet of an air filter after the air filter is used for a long 

time, thus affecting system ventilation and heat dissipation. It is recommended to clear the air 

filter once every three months. 

 

Users should select power module according to the total consumption power of purchased 

modules in order to ensure the power module consumption is greater than the consumption 

required by system. If the power consumption exceeds the power of a power module, please 

purchase another one. For calculation method, please refer to Power Supply Requirements in 

RG-S12000 Series Switch Hardware Installation Manua

l” 

 

It is recommended to use 1+1 dual power system redundant mode. However, if the total power 

consumptions of all modules exceed the maximum power of a single power system, the 

redundant backup function does not work. 

 

For 1+1 redundant configuration, configure different power sources for two power modules, for 

example, one is commercial power and the other is UPS power. 

 

Power supplies of one model must be configured for the dual power supplies. 

System Grounding   

Grounding Requirements 

Summary of Contents for RG-S12000 Series

Page 1: ...RG S12000 Series Switches Quick Installation Guide V1 22...

Page 2: ...ten consent of Ruijie Networks is prohibited are registered trademarks of Ruijie Networks Counterfeit is strictly prohibited Exemption statement This document is provided as is The contents of this do...

Page 3: ...ocuments Documents Description Configuration Guide Describes network protocols and related mechanisms that supported by the product with configuration examples Command Reference Describes the related...

Page 4: ...tion Requirements 8 Checking Before Installation 10 Fan 11 Power Supply 11 Specification 11 Precaution 11 System Grounding 11 Grounding Requirements 11 Grounding description 12 Rack grounding pole 12...

Page 5: ...rectly looking at the optical interfaces or fibers may damage your eyes Serial Interface Safety Warning Hot plugging in a serial interface may damage your terminal Please power off the terminal before...

Page 6: ...ngine modules and provides 4 service module slots Safety Precautions for Movement RG S12000 Series is large and heavy When you carry them please pay attention to the following requirements Remove all...

Page 7: ...damage you must pay attention to the following Proper grounding of the switch and floor Dust prevention measures are taken in the room An appropriate humidity is maintained Do not wear loose clothes...

Page 8: ...l fibers and distribution cables Connect the interfaces Ruler long tapeline marker pen Measure the installation position Common tools Bolts diagonal pliers straps Mount the chassis Anti static tool Pr...

Page 9: ...ent spacing is reserved at the ventilation openings to ensure normal heat dissipation After various cables have been connected they should be arranged into bundles or placed on the cabling rack to avo...

Page 10: ...not grounded reliably or the ground is wet Keep the switch away from wet or liquid Be aware of the emergent power switch in the room Once an accident occurs shut down the power switch Make sure that...

Page 11: ...bles to connect power modules The dust in the air may block the air outlet of an air filter after the air filter is used for a long time thus affecting system ventilation and heat dissipation It is re...

Page 12: ...bank Lightning prevention ground prevents lightning shock The lightning prevention system of general equipment is a separate system composed of lightning rod down conductor and grounding system Figure...

Page 13: ...ounding pole of the chassis The antistatic wrist strap jack is located on the front panel of the chassis marked with yellow ESD 4 The antistatic wrist strap is grounded well and the DC electric resist...

Page 14: ...d the Alarm LED is red Troubleshooting 1 Check if the supervisor engine gets loose If so install the supervisor engine again and ensure that it is inserted tightly before you tighten the fastening scr...

Page 15: ...Input delete config text Press Enter 5 The Are you sure you want to delete config text No yes is shown on the interface Input y and press Enter to delete it 6 Input dir to view current file configurat...

Page 16: ...connected to the receiving end of the other optical interface You can check by changing the sequence in which the two optical fibers are connected on the optical module 2 Check whether the optical mod...

Reviews: