RDV3040-PCIVisionCut operation manual V1.0
SHENZHEN RUIDA TECHNOLOGY
28
Picture 2-15-1 vendor pareameter-Motor settings
1.1 Motor settings
1) Direction polar
:
You can change the direction of the axis motion when you send positive pulse. For example, you have
defined the positive direction of a axis. If you find that the axis run to negative direction when you send a
positive movement, you should change the direction polar.
2) HOME switch polar
:
If the home switch output high level signal when the home switch is triggered, you should select
“
Hight
”
.
If the home switch output low level signal when the home switch is triggered, you should select
“
Low
”
.
NOTICE: the home switch must be according with the polar parameter. Or the going home process will
executed incorrectly.
3) Limit polar
:
If the limit switch output high level signal when the home switch is triggered, you should select
“
Hight
”
. If
the limit switch output low level signal when the home switch is triggered, you should select
“
Low
”
.
NOTICE: the limit switch must be according with the limit polar parameter. Or the motion control will
be prohibited.
4) Control signal
:
Pulse+dir signal is valid to motor control.
5) pulse equivalency
:
That means the quality of the pulse when axis move 1 millimeter.
6) Cut range
: