Miknetum MPR 900 Turbo
16
Also observe Chapter 1 Safety instructions!
Only qualified technicians may carry out repairs on the cool-
ing system of the machine!
Notify and obtain permission from Rühle customer service if
welding or cutting work is required on the machine!
Reaching into the inside of the machine by opening the side
covers is strictly prohibited when performing "Regular care"
activities!
When working on the electrical equipment of the machine,
ensure that
•
this is only done by qualified personnel!
•
the machine is always disconnected from the power
supply!
a waiting time of at least 10 minutes is observed after
switching off the machine to allow the capacitors of the fre-
quency converters to discharge to a harmless voltage level!
Use of lubricants
–
hygiene area
•
Multi-purpose grease OKS 476 white, for food technology
NSF H1
Reg. No. 137619
➢
Replacing seal rings
Use of lubricants
–
others
•
AUTOL TOP 2000, high pressure grease with synthetic base oil (soap
basis)
Personal protective equipment:
P
rotective gloves (EN 374), eye protection (EN 166),
protective clothing (EN 14605), protective mask (EN 1731)
➢
Replacement of moving parts, e.g. drive for swivelling the
drum, flange drive tumbling arm
•
5182 PYROSHIELD® SYN OPEN GEAR GREASE, synthetic high-perfor-
mance lubricant (synth. basic oils)
Protective equipment:
Protective gloves (EN 374), eye protection (EN 166),
protective clothing (EN 14605), facial protection (EN 1731),
Provide adequate ventilation before and after use. Do not eat, drink or
smoke during use!