The work area around the machine is at least 0.5 m on all sides; for
maintenance work it is at least 1 m; if used as passageway, it is at
least 1.2 m.
2.3
Connecting the machine
The machine is connected to a three-phase outlet (clockwise rotating
field); the specifications (voltage, amperage) must correspond to the
specifications on the type plate of the machine.
The machine must be shut down until a damaged power
supply line has been repaired!
Check the power supply line regularly!
Check the correct direction of the rotary field by starting
the machine. A message appears on the tablet PC if the
rotating field is wrong!
•
In this case, an electrician has to change the rotating
field inside the mains plug.
•
The power supply to the machine must be fuse-pro-
tected with 32A and protected with an AC/DC sensi-
tive RCD (type B).
3
Operating instructions
Please refer to the short instructions supplied with your machine for
the operation of your Miknetum.
Also observe Chapter 1 Safety instructions!
Make sure that you are connected to the right machine
with your tablet PC!
Depending on the application programs, the drum is
moved automatically. While the program is running, no
person may stand within the working range of the ma-
chine (front distance at least 1.2 m over the entire ma-
chine width).