Miknetum MPR 900 Turbo
19
1.
The machine contains a cooling system filled with the refrig-
erant R452A. It must be pumped off by a refrigeration in-
staller and then disposed of correctly!
2.
The following components contain oil:
a.
Lid drive (lubricating grease)
b.
Tumbling arm drive
c.
Mixing arm drive
d.
Slewing gear
e.
Lifting aid drive
f.
Vacuum pump
g.
Compressor (cooling unit)
All gears/motors except for the compressor are equipped with
oil draining screws. The compressor must be drilled open for
draining the oil.
7
Technical documentation
7.1
Technical data
Supply voltage:
400 V 50/60 Hz 3-phase/N/PE
Power consumption:
11.9 kW
Full-load current:
23.7 A
Back-up fuse max.:
32 A
Protection class:
IP54
Protection class:
1
Ambient temperature:
+2 to 40 °C
Dimensions, W x H x D:
1930 x 2450 x 2153 mm
Workplace, W x H x D
2844 x 3262 x 3219 mm
Machine weight:
1920 kg
Transport weight:
2480 kg
Container size:
900 litres
Max. filling:
675 litres
Refrigerant:
R452A, 0.76 kg
Mixing arm speed:
-25 to +25 rpm
Tumbling arm speed:
0 to +25 rpm