Injector IR 17
9
The work area around the machine, plus a container on the discharge
and operator side, is at least 0.5 m on all sides; for maintenance work
it is at least 1 m; if used as a passageway, it is at least 1.2 m.
2.3
Connecting the machine
The machine is connected to a three-phase outlet (clockwise rotating
field), the specifications (voltage, amperage) must correspond to the
specifications on the type plate of the machine.
The machine must be shut down until a damaged power
supply line has been repaired!
Check the power supply line regularly!
Check the correct direction of the rotary field by starting
the machine. The machine cannot be started if the
rotational field is wrong.
•
In this case, an electrician has to change the rotary
field inside the mains plug.
•
The power supply to the machine must be fuse-
protected with 16 A and protected with an AC/DC
sensitive RCD (type B).
3
Operating instructions
Please refer to the short instructions supplied with your machine for
operation of your Injector.
Also follow the safety instructions in chapter 1.1!
In its respective life cycle phases (transport,
commissioning, setup, operation, cleaning,
decommissioning, care/maintenance,
dismantling/disposal) this machine is designed for single
person operation!