Injector IR 17
5
!!! Before putting the machine into operation for the first time and on
each working day, the operator must check the functionality of the
following safety devices:
a) Visual check for changes or damage on all machine sides and
accessible machine parts, e.g. the curing needles. The
machine must be shut down in the event of any damage or
changes!
b) Check the safety switches as follows:
Close curing compartment door with
“discharge”
safety guard
as well as the
“intake”
safety guard.
•
Start the machine.
–
Turn the main switch to
“0 –
Off”
.
–
If
the machine has not switched off, it must be shut down
immediately!
•
Start the machine.
–
Lift the
“Inlet”
safety guard by 20
mm.
–
If the machine has not switched off, it must be
shut down immediately!
•
Start the machine.
–
Lift the
“Outlet”
safety guard by 20
mm.
–
If the machine does not switch off, it must be shut
down immediately!
!!! To shut down the machine, turn the main switch to
“0”
- OFF" and
the disconnect the power plug from the outlet! Secure the machine
against further use!
!!! The supervisor must arrange for the repair of the non-functional
safety device by a Rühle service engineer. Until the corresponding
parts have been repaired, the supervisor must ensure that the
machine or parts of the machine are not put into operation under any
circumstances!
!!! The cleaning personnel must observe the work procedures from the
“Cleaning”
work instructions prepared by the supervisor.