background image

 

Lebensmitteltechnik 

 

 

 

 

 

Translation of the original instructions 

 
 

 - Frozen meat cutter 

 

Type:

 

GR 50 

 

 
 

Rühle GmbH, Beim Signauer Schachen 10, D-79865 Grafenhausen 

Tel.: +49 7748-523-11, Fax: +49 7748-523-8511 

www.original-ruehle.de 

 

Summary of Contents for GR 50

Page 1: ...smitteltechnik Translation of the original instructions Frozen meat cutter Type GR 50 Rühle GmbH Beim Signauer Schachen 10 D 79865 Grafenhausen Tel 49 7748 523 11 Fax 49 7748 523 8511 www original ruehle de ...

Page 2: ...Operating instructions 9 4 Cleaning instructions 10 4 1 Safety instructions 10 4 2 Cleaning agents and disinfectants 11 4 3 Cleaning procedure 11 5 Service Care maintenance repair 12 5 1 Regular care 12 5 2 Regular maintenance 13 5 3 Repair and spare parts 13 6 Disposal 14 7 Technical documentation 14 7 1 Technical data 14 7 2 Electrical circuit diagram 15 8 EC Declaration of Conformity according ...

Page 3: ...A supervisor responsible person must be appointed for the machine This person must a Completely read and understand these operating instructions before transport commissioning setup operation cleaning decommissioning care maintenance as well as dismantling disposal b Prepare work instructions for the intended and safe transport commissioning setup operation cleaning decommissioning care maintenanc...

Page 4: ...ne into operation for the first time and on each working day the operator must check the functionality of the following safety devices a Visual check for changes or damages on all machine sides and accessible machine parts e g the cut off knife The machine must be shut down in the event of any damages or changes b Check the safety switches as follows Close hood 1 hood 2 and the door for the standa...

Page 5: ...d the supervisor must ensure that the machine or parts of the machine are under no circumstances put into operation The cleaning personnel must observe the work procedures from the Cleaning work instructions prepared by the supervisor The maintenance personnel may only carry out work specified as Regular care unless any other authorisation has been issued in writing by the manufacturer of the mach...

Page 6: ...ine must be disconnected from the mains when performing maintenance work The protective covers may be removed only while performing maintenance control cabinet side cover 1 3 Intended Use The frozen meat cutter may only be used for cutting frozen blocks of meat bone material fish vegetables or button up to a temperature of 20 C The max room temperature may be 12 C for reasons of food hygiene This ...

Page 7: ...y Rühle Rühle GmbH Lebensmitteltechnik shall not be liable for any damage resulting from non compliance with these operating instructions 2 1 Machine transport and setup Please refer to the short instructions supplied with the machine regarding transport and setup of the frozen meat cutter The machine and machine parts must be transported by 2 persons 1x operator of floor conveyor 1 transport supe...

Page 8: ... The machine is connected to a three phase current outlet its data voltage amperage must agree with the specifications on the type plate of the machine The machine must be decommissioned until a damaged power supply line has been repaired The power supply line must be regularly checked Swivel range of hood 2 Swivel range of hood 1 Swivel range of folding table Swivel range for door for standard tr...

Page 9: ...s in Chapter 1 1 In its respective life cycle phases transport commissioning setup operation cleaning decommissioning care maintenance dismantling disposal this machine is designed for 1 person operation When using this machine no other person may be present near the machine The exception 2 man operation Installation and removal of the cutting blades Transport of machine and machine parts Maintena...

Page 10: ...ppropriate material e g brushes rags is required and must be provided for the proper procedures of the above Cleaning products and disinfectants approved for the food product area and suitable against contamination e g protein limescale must be used The cleaning agents and disinfectants must be prepared to a solution as described in the product data sheet of the manufacturer Personal protective eq...

Page 11: ...Or Cleaning agents Alkaline cleaning Acidic cleaning Somplex F fat solvent Somplex foam acidic Disinfectants Tego 2000 Tego IMC Supplier Th Goldschmidt AG Goldschmidtstr 100 D 45116 Essen Tel 49 201 1730 1 4 3 Cleaning procedure Please refer to the short instructions supplied with your machine for carrying out the cleaning procedure Cleaning preparations To ensure optimum cleaning some components ...

Page 12: ...oves when working on the blades Make sure when working on the electrical equipment of the machine that this is only done by qualified personnel the machine is always disconnected from power 5 1 Regular care Regular care of the machine must be carried out at least once per week This prevents malfunctions and signs of wear Any abnormalities detected during regular care must be reported to the superv...

Page 13: ...y devices as outlined in Chapter 1 1 Safety Instructions b Test run with open machine caution moving parts c All inspection work specified under Regular Care d Replace the vertical knives e Resharpen and readjust the cut off knife f Check radial shaft seals for leak tightness replace otherwise g Fill all lubricating nipples and moving parts in the machine compartment with grease h Read operating h...

Page 14: ...isposed of at a recycling facility 7 Technical documentation 7 1 Technical data Connection voltage 400 V 50 60 Hz 3 phase AC N PE Power consumption 6 9 kW Full load current 13 3 A Back up fuse max 16 A Protection class IP54 Ambient temperature 2 C to 25 C Lowest permissible cut product temperature 20 C Size of standard trolley as per DIN 9797 200 litres Height of standard trolley as per DIN 9797 7...

Page 15: ... machine above the side cover In case of deviations contact the manufacturer for a written confirmation of the data If your country requires a ground fault circuit interrupting device as protective measure a ground fault circuit interrupting device type B AC DC sensitive must be used 7 2 Electrical circuit diagram The electrical circuit diagram of your machine is located in the electrical control ...

Page 16: ...lowing additional EU Directives and standards including any changes to these that are valid at the time of the declaration DIN EN 1672 2 2009 07 Food processing machinery Basic concepts Part 2 Hygiene requirements DIN EN 60204 1 2007 06 A1 2009 10 Safety of machinery Electrical equipment of machines Part 1 General requirements EC 1935 2004 Regulation on materials and articles intended to come into...

Reviews: