4. Installation Procedures
RuggedMAX™
25
Installation Guide Rev 1.0
The Data Adaptor unit includes a single output RJ-45 connector (for connection to an IEEE802.3
compatible device) that provides bi-directional 10/100 Base-T data and power to the outdoor
equipment over a Cat5e cable.
The unit receives power from 100V to 240V AC using an IEC-320-C14 industry standard
connector.
For information on the connector pinout, see
Section 4.4.2, “Assemble the PoE Connector”
.
The AC power supply cord should be 3 wires, 18 AWG minimum, with a length of less
than 4.5 m, and safety certified according to national rules.
Follow these steps to connect the base station Data Adaptor.
Procedure 4.6. Connecting the Base Station Data Adaptor
1. Connect the base station CD/ETH port to the Data Adaptor ODU IF port using the cable
you assembled earlier. For instructions on assembling the PoE cable, see
.
The maximum length of the indoor-to-outdoor CAT5 cable should not exceed
100m.
The Cat5e Ethernet cable is not included. Refer to
for detailed technical specifications.
2. Connect the Data Adaptor to a Switch/Router by connecting the Data Adaptor’s Ethernet port
and the Switch/Router 10/100 Base T-port using a Cat5e cable.
3. Connect the Data Adaptor to the 110V/220V AC mains using the supplied cable.
Before connecting the data adaptor to the main outlet, verify that all system
components are properly installed. Make sure that all cable connectors are
securely positioned in the appropriate ports.
4. Verify that the Data Adaptor LEDs located on the front panel are Green, indicating an OK
status.
LED
Color
Description
PWR
Green
Input power is connected
LAN
Green
LAN link/activity display
Table 4.2. Data Adaptor LED Indicators
4.4.8. Weatherproofing
DocBook content at xml:id="_Weatherproofing_Connectors" is missing from "../../RuggedMAX-
WiN7000-Installation-Guide/common/weatherproofing.xml".
Figure 4.14, “Base Station Connectors wrapped with Splicing and Electrical Tape”
station connectors wrapped with splicing and electrical tape, before the application of mastic or
duct sealing putty.