CLASSIC-LINE
ECO-LINE
Instruction manual
16
Open fire / grilling
This is only allowed if the fireplace is not fitted with an
automatically-closing door (model A1). To prevent
smoke spreading into the room, you should switch off any
devices liable to cause a depression, such as hoods and
other fan-operated systems.
Open-fire operation requires you to supervise the
fire at all times, in case of sparks.
1
OPEN the convection air regulator completely*
* if the system is fitted with one
→
Pull out the control
2
OPEN the combustion air regulator completely*
* if the system is fitted with one
→
Pull out the control
3
OPEN the smoke regulator completely *
* if the system is fitted with one
→
Turn the button to the left or right
(depending on the opening direction)
4
SWITCH OFF the fan or REDUCE fan speed*
* if the system is fitted with one
→
Turn the speed control button completely to the
right or left
(depending on your system)
5 OPEN the door completely
Use the protective glove provided in the user kit if
the fireplace has been in operation for a while.
6
INSTALL the grill system
→
The holding socket is built into the base
You will find a range of grilling accessories in our on-line
store:
www.ruegg-cheminee.com