Appendix C: Replacing the F Connector
Adapter
If you need to replace the 3/4’’ KS male to F female port adapter (stinger or hardline adapter), then
complete the following:
1
Collect the following tools and supplies:
o
Customer-supplied 3/4’’ KS male to F female port adapter (stinger)
o
7/16’’ (11mm) and 3/4’’ (19mm) open-end wrenches
o
No. 2 Phillips screwdriver
o
Torque wrench and/or torque screwdriver with sockets and bits
o
Wire cutters
o
100% silicon sealant
2
Using a 7/16’’ wrench, unscrew and remove the stinger screw-in access plug (1 in
) next
to the stinger F connector (2 in
Figure 16. F connector and plug
3
Using a No. 2 Phillips screwdriver, loosen the Phillips retaining screw holding down the existing
stinger pin only enough to release the stinger pin.
DO NOT
remove the Phillips retaining screw,
or it could fall down into the chassis of the T504.
4
Using the 3/4’’ wrench, unscrew and remove the stinger (2 in
5
Using the wire cutters, cut the new stinger pin to the same length as the old stinger pin.
shows the stinger pin length.