T504 AP Installation Guide, 800-71032-001 Rev D
Installing the T504
Deploying the T504
23
Installing the Cable Power Tap
The CATV coaxial cable used in the field deployment must have 40 to 90 VAC power multiplexed
with the RF signal on the coaxial cable, since the T504 Connector B is used for both electrical power
and the RF signal.
Ruckus Wireless recommends installing a cable power tap (Antronix MGT2000-SDPE tap, or
equivalent) close to the T504. Refer to the manufacturer’s instructions to mount the cable power tap
on the coaxial cable.
Figure 7
shows a typical cable power tap and connection to the CM using an
describes the elements in
Figure 7
.
NOTE
If the F connector on the T504 is damaged, then refer to
1
Use a customer-supplied cable, connect any port on the cable power tap to the F connector on
the T504.
2
Using a torque screwdriver or wrench, tighten the cable F connectors to 3.4N.m or 30in-lbs.
Figure 7. Cable Power Tap Connection to the T504 Cable Modem
Table 4. Typical cable power tap connections
No. Description
1
o
Line amplifier/high output node.
2
o
Typical cable power tap.
Note:
Use any connector on the power tap.
3
o
Cable modem.
2
1
3
2