T504 AP Installation Guide, 800-71032-001 Rev D
Installing the T504
Deploying the T504
24
Powering the T504 with POC
40 to 90 VAC POC is used when the T504 is mounted on a cable strand and powered via an F-type
coaxial cable connected to the HFC cable plant.
1
Remove the power jumper from the power tap to remove AC power out of the power tap.
2
Insert the F-type coaxial cable that is connected to the HFC cable plant to the F-type connector
on the T504. Power is supplied through a power passing tap on the CATV coax. The tap is
connected to F-type connector on the T504 as shown in
3
Finger tighten the coaxial cable connector and then tighten to 3.4N.m (30in-lbs).
4
Plug the power jumper back into the power tap to restore AC power out of the power tap.
5
When the T504 receives power, its LEDs flash on and off as it goes through a power-on self test
and then receives its AP and CM configurations from the cable operator.
NOTE
Normally, the T504 receives its AP and CM configurations from the cable operator. This
means that the installer does not need to manually configure either the AP or the CM part of the T504.
6
Wait until the T504
PWR, CM DS, CM US,
and
ONLINE
LEDs stop flashing and then remain on.
You have verified that the T504 is powered. Continue with
Summary of Contents for ZoneFlex 901-T504-US31
Page 2: ...2 T504 AP Installation Guide 800 71032 001 Rev D...
Page 4: ...4 T504 AP Installation Guide 800 71032 001 Rev D...
Page 40: ...T504 AP Installation Guide 800 71032 001 Rev D 40...
Page 44: ...T504 AP Installation Guide 800 71032 001 Rev D Weight 44...
Page 50: ...T504 AP Installation Guide 800 71032 001 Rev D 50...
Page 51: ...T504 AP Installation Guide 800 71032 001 Rev D 51...