7
1. INLET and OUTLET connection of the heater unit should not be
reversed, with stop valve installed on INLET. (Diagram 1)
Sambungan unit pemanas “INLET” dan “OUTLET” tidak boleh
songsang dan injap hentian mestilah di pasang pada “INLET”.
2. It is recommended that the unit should be mounted above
1.5m above the floor to bottom of the heater. (Diagram 1)
Pemasangan unit digalakkan mempunyai jarak 1.5m antara
lantai dengan bahagian bawah pemanas. (Rajah 1)
2
3. INSTALLATION PROCEDURES
TATACARA PEMASANGAN
8. Instantaneous water heater shall be equipped with a 2-pole control switch and own residual
current device.
Pemanas air segera hendaklah dilengkapi dengan kawalan suis 2-kutub dan memiliki peranti arus
berbaki.
9. Water heaters exceeding 3kW shall be permanently connected to a 20A/30A rated circuit
breaker/fuse with an isolator switch and residual current device.
Pemanas air yang melebihi 3kW hendaklah disambung secara tetap pada 20A/30A nilai arus
pemutus litar/fius dengan suis pengasing dan peranti arus berbaki.
INLET
Diagram 1
Rujah 1
7. Electrical loading Table 1:
Pendawaian elektrik Jadual 1:
Floor/ Lantai
stop valve
injap hentian
OUTLET