2. GENERAL INFORMATION
MAKLUMAT UMUM
CAUTION:
AWAS:
THIS APPLIANCE MUST BE EARTHED
PERKAKAS INI MESTI DIBUMIKAN
INSTALLATION
PEMASANGAN
1. All the plumbing work should be completed before proceeding to electrical wiring
connection. (Table 1)
Semua pemasangan paip perlu diselesaikan sebelum memulakan kerja-kerja penyambungan
wayar elektrik. (Jadual 1)
2. Installation must be carried out by qualified electrician with close reference to this manual
and in compliance with the local regulations.
Pemasangan mestilah dilakukan oleh juruteknik yang berkelayakan dengan merujuk pada
panduan ini dan mengikut akta-akta tempatan.
3. The unit works at minimum water flow rate of 2 litre/min, which then would trigger the
built-in pump (only for pump model), boostering a stronger shower spray.
Unit ini berfungsi pada kadar aliran air minima 2 liter/min, yang mengaktifkan pam dan kemudi-
annya meningkat pancuran semburan.
4. The built-in electronic Earth Leakage Circuit Breaker (ELCB) would cut-off the power supply to
heater in the event of current leakage of as low as 15mA.
“Earth Leakage Circuit Breaker (ELCB)” akan memutuskan bekalan kuasa sekiranya berlaku
kebocoran tenaga serendah 15mA.
5. The Thermal Cut-Off would automatically shut off the power supply shall there is any
abnormal rise of showering temperature.
Pemotongan haba berfungsi secara automatik akan memutuskan bekalan kuasa jika terdapat
kenaikan suhu secara tidak normal.
6. The unit only operates when there is sufficient water flow to trigger the flow switch.
Unit hanya akan beroperasi apabila terdapat aliran air yang cukup untuk mengaktifkan suis
aliran.