IMPORTANT NOTE:

 The power inverter will not operate most appliance designed to produce 

heat, such as hair dryers, coffee makers, irons, heaters, and toasters. The current use of most 
of these exceeds rated power watts, far beyond the capacity of this unit. The inverter may be 
used either while engine is running or turned off. However, the inverter may not operate while the 
engine is st arti ng, since t he bat t ery vol tage can drop  substantially during cranking. 
The power inverter draws less than 1.3 ampere from the battery when it is not  supplying 
power to the load. In most cases, the power inverter may be left connected to the battery 
when it is not in use, since it draws so little current. If the vehicle will not be used for several 
days, disconnect the power inverter from the battery. 
 

 
LOW BATTERY ALARM 

 
An alarm will sound when the voltage of the battery drops to 10.5volts. This indicates that the 
battery requires recharging. The user should stop operations at this time, since the power 
inverter will shut down automatically when battery voltage drops to 10.0 volts. 
If the low battery alarm sounds when the battery is fully charged, follow the steps for correcting 
the lack of output power in the Trouble Shooting Guide. The alarm will sound when the 
inverter is overloaded, or if there is an excessive voltage drop between the battery and the 
inverter. 
NOTE: The alarm may sound momentarily when the unit is being connected to, or 
disconnected from, the power source. This is normal and does not indicate any problem. 
 

INDICATORS AND CONTROLS 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

BATTERY OPERATING TIME 
 
 
 

 

Summary of Contents for RTM570

Page 1: ...POWER INVERTOR MODEL TM253 RTM570 INSTRUCTION MANUAL...

Page 2: ...mation Continous Power 1000 w Power 2000w Inlet Power DC12V Outlet Power AC230V UNITS 1 BATTERY LIGHT 2 ON OFF SWITCH 3 ACCUMALATOR CONNECTION CABLES 4 220V POWER SUPPLY 5 USB CONNECTION 6 GROUNDING C...

Page 3: ...in locations that meet the following requirements DRY Keep away from water Do not allow water to drip or splash on power inverter COOL Ambient air temperature should be between 50 degrees and 80 degre...

Page 4: ...n firmly FIGURE 2 See Figure 2 for the appropriate terminal connections DC INPUT CABLE SIZES cable sizes under 6 GROUND CONNECTION Max Watts Out Approx Fuse Reg Wire Gauge 100W 15A 20 150W 20A 18 200W...

Page 5: ...e easiest for the inverter to drive though larger resistive loads such as electric stoves or heaters require more power than the power inverter can deliver continuouly Inductive loads such as TV s and...

Page 6: ...rrent If the vehicle will not be used for several days disconnect the power inverter from the battery LOW BATTERY ALARM An alarm will sound when the voltage of the battery drops to 10 5volts This indi...

Page 7: ...condition is not harmful to the inverter but could damage the power source An audible alarm is sounded when input voltage drops to 10 5 volts The inverter shuts down when input voltage drops to 10 0...

Page 8: ...k condition of alligator clips Low Output Voltage Using average reading voltmeter Inverter is overloaded Input voltage below 11 0 volts Use true RMS reading meter Reduce load to continuous watts to ma...

Page 9: ...input and output protection Remarks All the input voltage is optional between 12V DC or 24 V DC ITEM S800 RTM570 RTM562 S1500 RTM564 S2500 S3000 Max continuous power 800W 1000W 1200W 1500W 2000W 2500...

Page 10: ...TM253 RTM570...

Page 11: ...1000 w 2000w DC12V AC230V 1 2 ON OFF 3 4 220V 5 USB 6...

Page 12: ...11 20 15 30 DC 10 20 300 300 10 30 24 6 1 inch...

Page 13: ...1 2...

Page 14: ...1 2 2 6 DC Max Watts 100W 15A 20 150W 20A 18 200W 25A 16 300W 35A 14 400W 50A 12 600W 2X35A 8 800W 3X35A 6 1000W 4X40A 4 1500W 4X40A 4 2000W 8X3 OA 2...

Page 15: ...3 AC 110 220 230 240 0 9 99 2 6 300 600...

Page 16: ...1 3 10 5 10 00 INDICATORS AND CONTROLS...

Page 17: ...1 2 10 5 65 C...

Page 18: ...10 20 watt 11 0 RMS 11 0 4...

Page 19: ...ts 10 5 0 5Volts AC 110V 120V or 220V 230V 240V 50HZ or 60HZ 5 20A 25A 35A 50A 35Ax2 35Ax2 40Ax3 KGS 0 9 0 95 1 1 05 1 15 1 2 2 5 1 2 2 5 Blister or Color box 12V DC 24 V DC S800 S1000 RTM562 S1500 S2...

Page 20: ...220V 230V 240V 50HZ or 60HZ 5 35Ax3 40Ax4 40Ax4 40Ax4 30Ax8 40Ax8 40Ax8 KGS 2 6 2 7 2 8 3 1 3 5 4 0 4 0 12V DC 24 V DC...

Reviews: