background image

 

 
 
 

INTRODUCTION 

 

To get the most out of your power inverter,  proper installation is critical. Please read the installation and 
operating instructions in this manual carefully  before installing and using your power inverter. Pay  special 
attention to the CAUTION: statements in this manual. CAUTION: statements identify conditions or practices 
which could result in damage to your power inverter or to other Equipment. 

 

 

The power source must provide between 11(20) and 15(30) volts DC and must be able to supply sufficient current to 
operate the load. As a rough guide line, divide the power consumption of the load (in watts) by 10(20) to obtain the 
current (in amperes) in the power source must deliver. 
Example: Load is rated at 300 watts. Power source must be able to deliver: 300 divided by 10=30 amperes. 
 
CAUTION: Rechargeable batteries and devices with rechargeable batteries may not be suitable for use with the power 
inverter. The rechargeable batteries, recharging transformer and/or the power inverter may be damaged when trying to 
recharge devices of 24 volts and higher. The power inverter will not operate from a 6 volt battery.Refer to the 
manufacturers specifications when using these devices. 

 
PLACEMENT OF THE INVERTER 

 
For best operating results, the inverter should be placed on a flat surface, such as the floor or seat of the vehicle. The 
inverter should only be used in locations that meet the following requirements: 
DRY — Keep away from water. Do not allow water to drip or splash on power inverter. 
COOL — Ambient air temperature should be between 50 degrees and 80 degrees F. Do not place the inverter on or near a 
heating vent or any piece of equipment which is generating heat above room temperature. If avoidable, do not place the 
inverter in direct sunlight. 
VENTILATED — Allow at least one inch of clearance around the power inverter for air flow. Do not place anything on 
or over the inverter during operation. 

 
 

Make sure that the air is allowed to circulate freely  around the unit. 
 

SAFETY —

 Do not use the power inverter  near flammable materials or in any location which 

may accumulate flammable fumes or gases, such as the  battery compartment of your car, 
truck, RV, or boat. This product is not suitable for use while traveling using battery clamps. 
The length of the wire cables and battery clamps are not designed for this operation. If you wish to 
operate the inverter while moving, the power inverter May be permanently mounted and wired. 
 

CONNECTING TO THE POWER SOURCE 

 

Your power inverter does not come equipped with battery cables which must be purchased 
separately. The proper gauge of the battery cables can only be properly determined when 
Calculating the length of the cables from the inverter to the battery. These cables may be 
purchased from any automotive, marine or home center. (See Fig. 1 and Fig. 2) 
 

CAUTION:

 DO NOT USE WITH POSITIVE  GROUND 

 

ELECTRONICAL SYSTEMS. 

 

C A U T I O N :

M A K E   S U R E   T H E   P O W E R   INVERTER IS OFF. 

 
 
 

Summary of Contents for RTM570

Page 1: ...POWER INVERTOR MODEL TM253 RTM570 INSTRUCTION MANUAL...

Page 2: ...mation Continous Power 1000 w Power 2000w Inlet Power DC12V Outlet Power AC230V UNITS 1 BATTERY LIGHT 2 ON OFF SWITCH 3 ACCUMALATOR CONNECTION CABLES 4 220V POWER SUPPLY 5 USB CONNECTION 6 GROUNDING C...

Page 3: ...in locations that meet the following requirements DRY Keep away from water Do not allow water to drip or splash on power inverter COOL Ambient air temperature should be between 50 degrees and 80 degre...

Page 4: ...n firmly FIGURE 2 See Figure 2 for the appropriate terminal connections DC INPUT CABLE SIZES cable sizes under 6 GROUND CONNECTION Max Watts Out Approx Fuse Reg Wire Gauge 100W 15A 20 150W 20A 18 200W...

Page 5: ...e easiest for the inverter to drive though larger resistive loads such as electric stoves or heaters require more power than the power inverter can deliver continuouly Inductive loads such as TV s and...

Page 6: ...rrent If the vehicle will not be used for several days disconnect the power inverter from the battery LOW BATTERY ALARM An alarm will sound when the voltage of the battery drops to 10 5volts This indi...

Page 7: ...condition is not harmful to the inverter but could damage the power source An audible alarm is sounded when input voltage drops to 10 5 volts The inverter shuts down when input voltage drops to 10 0...

Page 8: ...k condition of alligator clips Low Output Voltage Using average reading voltmeter Inverter is overloaded Input voltage below 11 0 volts Use true RMS reading meter Reduce load to continuous watts to ma...

Page 9: ...input and output protection Remarks All the input voltage is optional between 12V DC or 24 V DC ITEM S800 RTM570 RTM562 S1500 RTM564 S2500 S3000 Max continuous power 800W 1000W 1200W 1500W 2000W 2500...

Page 10: ...TM253 RTM570...

Page 11: ...1000 w 2000w DC12V AC230V 1 2 ON OFF 3 4 220V 5 USB 6...

Page 12: ...11 20 15 30 DC 10 20 300 300 10 30 24 6 1 inch...

Page 13: ...1 2...

Page 14: ...1 2 2 6 DC Max Watts 100W 15A 20 150W 20A 18 200W 25A 16 300W 35A 14 400W 50A 12 600W 2X35A 8 800W 3X35A 6 1000W 4X40A 4 1500W 4X40A 4 2000W 8X3 OA 2...

Page 15: ...3 AC 110 220 230 240 0 9 99 2 6 300 600...

Page 16: ...1 3 10 5 10 00 INDICATORS AND CONTROLS...

Page 17: ...1 2 10 5 65 C...

Page 18: ...10 20 watt 11 0 RMS 11 0 4...

Page 19: ...ts 10 5 0 5Volts AC 110V 120V or 220V 230V 240V 50HZ or 60HZ 5 20A 25A 35A 50A 35Ax2 35Ax2 40Ax3 KGS 0 9 0 95 1 1 05 1 15 1 2 2 5 1 2 2 5 Blister or Color box 12V DC 24 V DC S800 S1000 RTM562 S1500 S2...

Page 20: ...220V 230V 240V 50HZ or 60HZ 5 35Ax3 40Ax4 40Ax4 40Ax4 30Ax8 40Ax8 40Ax8 KGS 2 6 2 7 2 8 3 1 3 5 4 0 4 0 12V DC 24 V DC...