19
It’s Under Control
®
CHAPter 4 | COnneCtIOn OPtIOns
reAr Ir
RF or IR Receivers
Examples:
InFrAred termInAls And COnneCtIOns
termInAl: +12VdC
Positive power supply connection. It is internally tied to the Power
jack. This can be used to power external IR or RF receivers.
termInAl: GrOund
Common ground connection. Use this ground reference for any device
that is connected to the +12VDC, SIGNAL IN, OR HIGH OUT terminals.
termInAl: sIGnAl In
Input connection for system trigger codes. This should be connected to
an RTI RF receiver or industry standard IR repeater system. The signal
voltage can be from 3VDC - 12VDC.
termInAl: HIGH Out
High current (200mA) IR output connection. This can be used to power
up to 10 infrared mini-emitters, an IR blaster, or extending IR control
over a long distance (1000 ft. max).
To Source Equipment,
Surround Processors,
Lighting Systems, etc.
Optional accessories shown
are sold separately.