15
It’s Under Control
®
11. Status
Mono input jack (3.5mm) provides a +12VDC voltage output when any zone
is turned on (15mA max). This can be used to trigger external equipment.
When all zones are turned off, 0VDC is present.
12. +12VDC
Mono input jack (3.5mm) provides a co12VDC output (500mA max).
13. RS-232
DB-9 jack for RS-232 control of the AD-16x from a control system.
14. ID Number - Discrete IR Control
Up to 8 AD-16x matrix switches can be installed to distribute audio sources
to 128 output zones*. Each AD-16x can be assigned a unique ID number
to allow discrete IR control. Discrete IR code libraries are available for
each unique ID. To set the unique ID for each AD-16x unit, refer to the ID
assignment chart to the right of the 3 switches and adjust as necessary.
*NOTE: Up to eight AD-16x units may be used to reach 128 output zones
using Infrared control. There is a limit of four AD-16x units when the AD64
two-way driver is used, for a maximum of 64 output zones.
15. Ethernet Port
The Ethernet port (RJ45) allows for bi-directional control from an RTI XP
series control processor over an Ethernet network (LAN). A two-way driver
is available on the RTI website (dealer section) that will enable this type of
control.
16. AC Power Socket and Fuse
A three-pin grounded socket that connects with a removable AC power cord
with a T5AL 250V fuse.
17. PRE-OUT Outputs
Provides line level audio outputs for driving external amplifiers, such
as the RTI CP-450 or CP-1650 amplifiers. The switch can be set to
VAR or FIX.
•
VAR
- The output level is variable and will ramp up and down with the
corresponding AD-16x zone volume control.
•
FIX
- The ouput level is fixed and is not affected by the corresponding
AD-16x zone volume control.
Using this setting requires an external
amplifier which supports volume control.
CHAPTER 2 | FEATURES AND DESCRIPTION
AD-16X REAR PANEL QUICK REFERENCE
Summary of Contents for AD-16x
Page 8: ...Audio Matrix Switch AD 16x 8...
Page 11: ...11 It s Under Control...
Page 31: ...31 It s Under Control CHAPTER 3 INSTALLATION AND OPERATION WEB INTERFACE NETWORK PAGE...
Page 33: ...33 It s Under Control WEB INTERFACE ZONES PAGE CHAPTER 3 INSTALLATION AND OPERATION...
Page 35: ...35 It s Under Control WEB INTERFACE GROUPS PAGE...
Page 36: ...Audio Matrix Switch AD 16x 36...
Page 39: ...39 It s Under Control...
Page 42: ...Audio Matrix Switch AD 16x 42...
Page 46: ...Audio Matrix Switch AD 16x 46 NOTES...
Page 47: ...47 It s Under Control NOTES...