Factory-Configured Switch and Jumper Settings
Table 1-1 lists the factory settings of the user-configurable jumpers and switch on the 210/5210. Figure 1-1
shows the module layout and the locations of the factory-set jumpers. The following paragraphs explain how to
change the factory settings. Pay special attention to the setting of S1, the base address switch, to avoid address
contention when you first use your module in your system.
Table 1-1: Factory Settings
Switch/
Jumper
Function Controlled
Factory Settings
(Jumpers Installed)
P3
Selects the active interrupt channel; pulls tri-state
buffer to ground (G) for multiple interrupt
applications
Interrupt channels disabled; jumper
installed on G (ground for buffer)
P4
Sets the clock sources for the 8254 timer/counters
(TC0-TC2)
Jumpers installed on CLK0-OSC,
CLK1-OT0 & CLK2-OT1 (cascaded)
P5
Sets the analog input voltage range
10V
P6
Sets the analog input voltage polarity
+/-
P7
Selects one of three signals as the interrupt
source
OT2
P8
8255 Port B, bits 4-7, pads for user connections
No connections installed
S1
Sets the base address
300 hex (768 decimal)
Fig. 1-1 — Module Layout Showing Factory-Configured Settings