background image

Document # 2012-XLIN 

  

1375 Willow Lake Blvd. #103 

Vadnais Heights, MN 55110 

877-206-5800

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 

 

 

 
 
 

 

 

*A Videofied CMA601 or XMB611/XMA611 Alphanumeric Keypad is required for 

programming and maintenance 

COMPLETE SETUP AND PROGRAMMING MANUAL 

FOR 

XL600 GPRS PANEL 

 

CMA601 

XL600 GPRS 

XMB611/XMA611 

Summary of Contents for XL600

Page 1: ...Blvd 103 Vadnais Heights MN 55110 877 206 5800 A Videofied CMA601 or XMB611 XMA611 Alphanumeric Keypad is required for programming and maintenance COMPLETE SETUP AND PROGRAMMING MANUAL FOR XL600 GPRS PANEL CMA601 XL600 GPRS XMB611 XMA611 ...

Page 2: ...nd Access Codes 14 Disabling Monitoring 15 Choosing Siren Options 16 Testing to Central Station 17 Scheduling 18 20 Mounting the XL 21 Testing GPRS Level 21 Testing RF Level 22 User Functions 23 26 Troubleshooting 27 28 Central Station not getting Video 27 Central Station not getting any Signals 28 Panel saying Connected with Monitor Station 28 Unable to record device or getting Pairing Failure er...

Page 3: ...termined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tec...

Page 4: ... need to move the device to get optimal signal Page 22 Note There are no external antenna options for the XL control panel For cellular issues a third party cellular repeater may be used to increase signal Note Re enable monitoring before you send signals page 14 8 5 If you are currently using TMT Installer to program the system you can take still pictures from each MotionViewer using the software...

Page 5: ... must follow the specifications in the table below Type Specifications Location In Manual Audio When a MotionViewer is installed on the system you may not have the siren sound for less than 60 seconds Page 26 Audio If no MotionViewer is installed on the system you may not have the siren sound for less than 240 seconds Page 26 Delays When a MotionViewer is installed on the system the Entry delay mu...

Page 6: ...5v Alkaline D Cell Used for Installations without power available Install the SIM card Put the SIM card on the plastic take care to respect the right direction Slide it in the connector Connect the battery connector on the Cover board and wait for 20 seconds before proceeding The SIM card must NOT be inserted or removed while the panel is powered Power the Control Panel ...

Page 7: ... ENGLISH or for language selection YES to apply RADIO RANGE TEST RF TEST x 9 YES YES Other languages are available by scrolling with arrows ITALIANO NEDERLANDS DEUTSCH CASTELLANO SVENSKA PORTUGUES FRANCAIS Press YES for the selected one LED will Dance BEEP The Radio Range test must be run during the learn in process in order to ensure proper pairing with the control panel This test is the strength...

Page 8: ...le the screen changes Name the installer code using the alphanumeric keypad If you leave it blank and press YES it will be named ACCESS 1 Use the or to set the Year Use the or to set the Month Use the or to set the Day Use the or to set the Hour From here until the end of the programming you will not be able to step back to a previous parameter All parameters can be changed after initial programmi...

Page 9: ... 09 10 53 ENTRY COMPLETE CONNECTED TO MONITOR STATION ACCOUNT NUMBER ACCOUNT NUMBER PERIODIC TEST 24 HOURS or for period selection and YES to apply CODE STATE MODIFICATION AREAS CONFIGURATION AREA NAME 1 EXIT DELAY 45 sec Other values are available 2 min 1 min 45 sec Use the arrows for the selection and YES to confirm Other values are available 2 min 1 min 45 sec 30 sec 15 sec Use the arrows for t...

Page 10: ...t parameter Your PASSWORD is given to you by your Cellular Provider Press YES to enter into the parameter and use the Keypad to complete the name Press YES to confirm your entry and the arrow to move to the next parameter Your IP1 address is given to you by your Central Station Press YES to enter into the parameter and use the Keypad to complete the address Press YES to confirm your entry and the ...

Page 11: ...eo alarms Each device has a unique programming button Please reference the Installation Sheet for the device you would like to program Before completing programming make sure that all tampers are depressed by verifying that each devices indicator LED is off Device Type Recorded RADIO RANGE TEST RADIO RANGE TEST RF TEST x 9 YES YES AREA ALLOCATION NAME LOCATION FUNCTIONAL DEVICE TEST ESC NO YES YES...

Page 12: ...2011 11 28 E2 5 Installation Manual for XL600GPRS 12 P a g e ...

Page 13: ... EMAIL SENDER ENTER A NEW EMAIL ADDRESS SELECT MODIFY EMAIL ADDRESS VIDEOMAIL ALARM ADDRESS AREAS AND DEVICES DEVICES ADD A NEW DEVICE DEVICE CONFIGURATION DEVICES LIST DELETE DEVICE CHANGING NAME CHANGING AREA 24 HOUR DEVICE 24 HOUR SIREN MODE AREAS AREAS LIST AREA CONTENT LIST OF DEVICES IN AREA CHANGING NAME AREA SIREN DURATION INTRUSION 90sec SIREN DURATION TAMPER 90sec ENTRY DELAY 15 sec EXIT...

Page 14: ...uress The XL system can accept up to 19 Badges or Access codes in any combination 10 12 27 10 53 DISARMED LVL 3 BADGES ACCESS CODES BADGE OR CODE ENTER A BADGE CODE BADGE OR CODE YES Badge Presented Press the arrow to move to BADGES ACCESS CODES Enter the Installer code Enter a 4 6 digit user code or present a badge to the reader for 2 seconds NAME OF BADGE CONFIRM THE CODE CODE NAME ENTRY COMPLET...

Page 15: ...that you will have access to programming throughout your troubleshooting Press YES on MONITORING ENABLED and use the to change the value to DISABLED and press YES to lock it in Use the to move to CONFIGURATION MONITOR STATION Press YES on MONITORING PARAMETERS Press the to move to CONFIGURATION Enter the installer code for the system Enter the installer code for the system Press the arrow to move ...

Page 16: ...WITHOUT SIREN BADGE OR CODE Enter the Installer code followed by YES Press YES to keep the default AREAS and STATE which will arm all devices on the Videofied system Use the arrow keys to modify the type of siren that the default FULLY ARMED profile will use when an alarm is triggered Alarm Siren Descriptions Siren All sounders on the system will be triggered when the system goes into alarm Entry ...

Page 17: ...g YES the keypad will tell you which device has been triggered Press YES to continue Once the delay has expired and the keypad says SYSTEM ARMED put motion in front of a MotionViewer If the MotionViewer is in area 1 you will need to wait for the entry delay to expire before disarming the system Once the system has gone into alarm enter a User Code followed by YES or present a badge to the reader t...

Page 18: ...2011 11 28 E2 5 Installation Manual for XL600GPRS 18 P a g e ...

Page 19: ...2011 11 28 E2 5 Installation Manual for XL600GPRS 19 P a g e ...

Page 20: ...2011 11 28 E2 5 Installation Manual for XL600GPRS 20 P a g e ...

Page 21: ...ed Check the IP address Domain Name and Port How to Mount the Control Panel Fix the back casing on the wall with 4 screws and one screw for the tamper 10 12 27 10 53 DISARMED LVL 3 GPRS LEVEL TEST IN PROG YES END Press the arrow to move to MAINTENANCE Press the arrow to move to GPRS LEVEL GPRS LEVEL Press and hold ESC NO for 5 seconds to return to the main menu This test can take up to 5 minutes t...

Page 22: ... 5 seconds to return to the main menu This test will run as long as you need it to Pressing the YES ESC NO or CLR buttons will end the test This test will show the results on the display of the keypad relative to the number of successful pings to the panel It is required to run the test for at least 30 seconds at the mounting location for accurate results and to have a 9 9 for reliable transmissio...

Page 23: ...ile Disarming the system Wake up the touchpad Put your badge on the reading area if the badge is correct the system will disarm automatically Enter you code and press OK or the disarming key Acknowledging events After the disarming or in disarmed mode the user shall acknowledge all events In case of multiple events each event must be acknowledged Each event is presented in two steps First step the...

Page 24: ...ify Device ID 0 for the panel and value from 1 to 19 for other devices for tamper intrusion or other troubles Trouble ID C for bad code Means there is an intrusion detected For other troubles Radio Jamming etc Keys and symbols for arming and disarming Meaning Use to disarmed the system Key is used to arm the system in STAY mode Symbol is lighted when system is armed in STAY mode Key is used to arm...

Page 25: ...ge the GPRS antenna 2 Touchpad commands will allow you to perform certain tasks from the XL touchpad For any command you start by pressing the symbol and holding for 3 seconds All numbers on the touchpad will start blinking on and off Code Function 000000 OK Keypad Enrollment 000100 OK 0 Disable 1 Enable the Green Battery light 888200 OK GPRS Signal Strength 8883XX OK XX is the zone of the test Ra...

Page 26: ... adjust the siren length after initial programming has been completed 5 The CMA610 and XMB611 XMA611 are supervised devices and must be permanently mounted after programming and testing have been completed These products are not intended for portable use AREAS AND DEVICES SIREN DURATION INTRUSION 60 Using the programming keypad you must navigate to the AREAS AND DEVICES menu in CONFIGURATION Press...

Page 27: ...el Device Locating will test the RF signal strength between the device and the Control Panel For reliable transmission this result must be a 9 9 This is the number of successful pings between the device and the Control Panel so a loss of just 1 packet could cause failure to transmit video Important Note Videofied will only automatically download the first MotionViewer video that is taken and only ...

Page 28: ...ED WITH MONITOR STATION While the Control Panel is attempting or is connected with the Monitoring Station you will see this message when you attempt to move around on the keypad If the system is not successful in connecting with the station it will retry the connection multiple times locking you out of programming until it is done trying This normally take anywhere between 15 20 minutes If you wan...

Page 29: ...ramming Button Of Device o 3 Insert a single battery into the device o 4 Wait 1 second for device to power up o 5 Press programming button of device for keypads press CLR ESC NO keys at the same time For the 4 button remote keyfobs the process is slightly different o 1 Press and hold the ON and OFF keys at the same time for 12 seconds o 2 Wait 1 second o 3 Press and hold the ON and OFF keys at the...

Page 30: ...2011 11 28 E2 5 Installation Manual for XL600GPRS 30 P a g e ...