ENVIRONMENTAL INFORMATION 

Packaging:

The materials used in the packaging of Full Gauge products are 100% recyclable. Try 
to perform disposal through specialized recyclers.

Product:

The  components  used  in  Full  Gauge  controllers  can  be  recycled  and  reused  if 
disassembled by specialized companies.

Disposal:

Do not incinerate or dispose the controllers that have reached the end of their service 
as household garbage. Observe the laws in your area regarding disposal of electronic 
waste. If in doubt, please contact Full Gauge Controls.

W

ARRANTY

 - FULL

 GAUGE CONTROLS

Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) year 

warranty,  as  of  the  date  of  the  consigned  sale,  as  stated  on  the  invoice.  They  are 
guaranteed  against  manufacturing  defects  that  make  them  unsuitable  or  inadequate  for 
their intended use.

EXCEPTIONS TO WARRANTY

The  Warranty  does  not  cover  expenses  incurred  for  freight  and/or  insurance  when 

sending  products  with  signs  of  defect  or  faulty  functioning  to  an  authorized  provider  of 
technical support services. The following events are not covered either: natural wear and 
tear of parts; external damage caused by falls or inadequate packaging of products.

LOSS OF WARRANTY

Products will automatically lose its warranty in the following cases:
- The instructions for assembly and use found in the technical description and installation 

procedures in Standard IEC60364 are not obeyed;

-  The  product  is  submitted  to  conditions  beyond  the  limits  specified  in  its  technical 

description;

- The product is violated or repaired by any person not a member of the technical team of 

Full Gauge Controls;

- Damage has been caused by a fall, blow and/or impact, infiltration of water, overload 

and/or atmospheric discharge.

USE OF WARRANTY

To make use of the warranty, customers must send the properly packaged product to Full 

Gauge  Controls  together  with  the  invoice  or  receipt  for  the  corresponding  purchase. As 
much  information  as  possible  in  relation  to  the  issue  detected  must  be  sent  to  facilitate 
analysis, testing and execution of the service.

These procedures and any maintenance of the product may only be provided by Full 

Gauge Controls Technical Support services in the company's headquarters at Rua Júlio de 
Castilhos, 250 - CEP 92120-030 - Canoas - Rio Grande do Sul – Brasil

Copyright 2020

All rights reserved.

Rev. 03

Summary of Contents for LogiTemp MT-514E FASTON

Page 1: ...LogiTemp Electronic Controller System Operations Manual Full Gauge Version MT514 PN 171571 REV 3 22 ...

Page 2: ...bles can be increased by user himself to up to 200 meters using a PP2x24 AWGcable 5 3 Recommendations of IEC60364 standard a Installoverloadprotectorsinthecontrollersupply b Install transient suppressors suppressor filter RC in the circuit to increase the service life of the controllerrelay Seeconnectioninstructionsofthefilteronthepreviouspage c The sensor cables may be together but not in the sam...

Page 3: ...ck touch maximum and minimum temperature display Hold down for 2 seconds inhibit audible alarm buzzer Pressed for 5 seconds turn on turn off the control functions Vinylprotector ImageIX item13 Protects the controller should when installed in a place with splashing water such as in refrigerated counters Thisadhesivevinylaccompaniestheinstrument onthepackaging IMPORTANT Applyonlyaftercompletingelect...

Page 4: ...state when powering up the instrument Temperature indication locked during defrost Delay in powering up the instrument delay Compressor status with sensor disconnected Time the compressor was on in case of an error Time the compressor was off in case of an error Max Time the compressor was on without reaching the setpoint Low temperature alarm High temperature alarm Output Operating Mode OUT2 Fan ...

Page 5: ... if configured as auxiliary compressor F26 7 Every time the OUT1 output is activated the time configured in this function will elapse beforeactivatingtheOUT2output F32 Alarminhibitiontimewhenenergizingthecontroller This is the time during which the alarm remains off even under conditions of alarm during the instrument start up This time will be counted after elapsing of the time configured in F19 ...

Page 6: ...of end of defrost process Control functions off Contact Full Gauge Controls Reconfigure the values of the functions OFF eCAL pppp Low temperature alarm Atlo inib LOC On LOC OFF AVoL AOPn OpEn Power outage alarm indication Open door alarm indication Open door indication Functions lockdown Unlocking of functions Buzzer inhibited Athi ALrC High temperature alarm Compressor reached maximum time on lim...

Page 7: ...t covered either natural wear and tear of parts external damage caused by falls or inadequate packaging of products LOSS OF WARRANTY Products will automatically lose its warranty in the following cases The instructions for assembly and use found in the technical description and installation procedures in Standard IEC60364 are not obeyed The product is submitted to conditions beyond the limits spec...

Page 8: ... U Hudson WI 54016 800 955 5253 Norlake Foodservice Sales 800 477 5253 Norlake Scientific Sales 800 388 5253 Norlake Parts Service 800 647 1284 Master Bilt Sales 800 684 8988 Master Bilt Parts Service Email rsgservice refsg com PN 171571 REV 3 22 ...

Reviews: