LogiTemp™
Electronic Controller System
Operations Manual
(Full Gauge Version MT514)
PN: 171571
REV 3/22
Page 1: ...LogiTemp Electronic Controller System Operations Manual Full Gauge Version MT514 PN 171571 REV 3 22 ...
Page 2: ...bles can be increased by user himself to up to 200 meters using a PP2x24 AWGcable 5 3 Recommendations of IEC60364 standard a Installoverloadprotectorsinthecontrollersupply b Install transient suppressors suppressor filter RC in the circuit to increase the service life of the controllerrelay Seeconnectioninstructionsofthefilteronthepreviouspage c The sensor cables may be together but not in the sam...
Page 3: ...ck touch maximum and minimum temperature display Hold down for 2 seconds inhibit audible alarm buzzer Pressed for 5 seconds turn on turn off the control functions Vinylprotector ImageIX item13 Protects the controller should when installed in a place with splashing water such as in refrigerated counters Thisadhesivevinylaccompaniestheinstrument onthepackaging IMPORTANT Applyonlyaftercompletingelect...
Page 4: ...state when powering up the instrument Temperature indication locked during defrost Delay in powering up the instrument delay Compressor status with sensor disconnected Time the compressor was on in case of an error Time the compressor was off in case of an error Max Time the compressor was on without reaching the setpoint Low temperature alarm High temperature alarm Output Operating Mode OUT2 Fan ...
Page 5: ... if configured as auxiliary compressor F26 7 Every time the OUT1 output is activated the time configured in this function will elapse beforeactivatingtheOUT2output F32 Alarminhibitiontimewhenenergizingthecontroller This is the time during which the alarm remains off even under conditions of alarm during the instrument start up This time will be counted after elapsing of the time configured in F19 ...
Page 6: ...of end of defrost process Control functions off Contact Full Gauge Controls Reconfigure the values of the functions OFF eCAL pppp Low temperature alarm Atlo inib LOC On LOC OFF AVoL AOPn OpEn Power outage alarm indication Open door alarm indication Open door indication Functions lockdown Unlocking of functions Buzzer inhibited Athi ALrC High temperature alarm Compressor reached maximum time on lim...
Page 7: ...t covered either natural wear and tear of parts external damage caused by falls or inadequate packaging of products LOSS OF WARRANTY Products will automatically lose its warranty in the following cases The instructions for assembly and use found in the technical description and installation procedures in Standard IEC60364 are not obeyed The product is submitted to conditions beyond the limits spec...
Page 8: ... U Hudson WI 54016 800 955 5253 Norlake Foodservice Sales 800 477 5253 Norlake Scientific Sales 800 388 5253 Norlake Parts Service 800 647 1284 Master Bilt Sales 800 684 8988 Master Bilt Parts Service Email rsgservice refsg com PN 171571 REV 3 22 ...