Combustible Gas Leak Detector/English
12
13/08/2017 Version No. 001
10-Storage
11-Disposal
After warming up for 40s the MICRO Combusitble Gas Leak Detector will be under
measurement status. Then press both the High/Low Sensitivity button and the buzzer
button all the time and it will beep, which means it is under factory setting status. Keep
pressing both the High/Low Sensitivity button and the buzzer button and also press
vibration button 4 times and then the Autozero button 4 times, the equipment will
produce a beep successfully, Icon(RESET) will be diplayed on the LCD which means you
have entered to resume production setting mode. At this time all the buttons can be
released. After RESET icon dispear the user has finished factory setting.
The MICRO Combusitble Gas Leak Detector must be stored in a dry secure area between
-10°C(14°F)and 60°C(158°F).
Store the tool in a locked area out of the reach of children and people unfamiliar with the
MICRO Combusitble Gas Leak Detector.
Remove the batteries before any long period of storage or shipping to avoid battery
leakage.
Parts of the MICRO Combusitble Gas Leak Detector contain valuable materials and can be
recycled. There are companies that specialize in recycling that may be found locally.
Dispose of the components in compliance with all applicable regulations. Contact your
local waste management authority for more information.
12-Troubleshooting
PROBLEM
Pressing and releasing the
ON/OFF button for one
second. But meter does not
work.
All display are flashing and
beeping at the same time.
The logo CAL will flash
when exiting calibration
POSSIBLE REASON
The battery is discharged
The batteries are low and
need to be charged.
The sensor(or the sensor
heater) is defective.
The calibration is wrong
SOLUTION
Shut OFF unit. Sensor or
entire unit should be
checked or replaced.
Check the meter and
environment, do calibration
again, if it still flashes, you
can contact the after-sales
Détecteur de fuite de gaz combustible
Manuel d'instructions
FR
RS GD-38
No d'inventaire: 144-5341
9-Restore factory settings