background image

Summary of Contents for ICA32N

Page 1: ...INSTRUCTION MANUAL ICA32N AC DC CURRENT TRANSDUCER EN IT DE FR ICA32N...

Page 2: ...1 ICA 32N CURRENT ADAPTOR INSTRUCTION MANUAL...

Page 3: ...2...

Page 4: ...aptor for digital meters complete with coiled output cable fitted with connectors 2 Carrying case 3 Operating manual Markings on the unit Attention Follow the operating instructions Symbol for double...

Page 5: ...connectors 1 Red LED Battery voltage low 2 Green LED Power on 3 Coiled output cable Voltage output signal 4 On off and function switch Slide switch for selecting measuring function 5 Zeroing potentio...

Page 6: ...5 Fig 1...

Page 7: ...0A Accuracy A c currents at 45 to 65Hz 100A range 0 to 100A 2 2A 600A range 100 to 400A 2 2A 600A range 400 to 600A 2 5 2A Output voltage 100A range a c d c 10mV A 600A range a c d c 1mV A Output impe...

Page 8: ...torage temperature 20 to 60 C 80 RH Temperature coefficient 0 2 x specified accuracy C 18 C or 28 C Power supply One 9V battery NEDA 1604 IEC6F22 Battery life alkaline 45 hours typical Max conductor d...

Page 9: ...lative humidifies or expose it to direct sunlight 6 Before changing the battery switch the adaptor off and unplug the output connectors from the meter 7 Take the battery out if you are not going to be...

Page 10: ...ck into the input sockets of a digital multimeter and set the multimeter to an d c voltage range of 200mV or 2V 3 Adjust the zeroing potentiometer to give a reading of 0 on the multimeter display 4 Wh...

Page 11: ...10 BLACK RED Current flow Fig 2...

Page 12: ...nt face down on a work surface and unscrew the screw holding the battery cover 3 Slide the battery cover to one side and remove the battery 4 Fit a new 9V battery close the cover and screw the screw b...

Page 13: ...h Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com Asia RS Components Pte Ltd 31 Tech Park Crescent Singapore 638040 www rs components com Europ...