6
(2) Technical specification
The figures given are for 23°C ±5°C, <75% RH.
Ranges :
0 to 100/600A
0 to 100/600A
Accuracy :
A.c. currents at 45 to 65Hz
100A range (0 to 100A
/
) ±(2% + 2A)
600A range (100 to 400A
/
) ±(2% + 2A)
600A range (400 to 600A
/
) ±(2.5% + 2A)
Output voltage
100A range (a.c./d.c.)
10mV/A
600A range (a.c./d.c.)
1mV/A
Output impedance :
100k
Ω
min. (a.c./d.c.)
Jaw position error :
±1% of reading
Method of sensing :
Hall effect for a.c. and d.c.