background image

Africa 

RS Components SA 

P.O. Box 12182, Vorna Valley, 1686

 

20 Indianapolis Street, Kyalami Business Park,  

Kyalami, Midrand 

South Africa 

www.rs-components.com

 

 

 

China 

RS Components Ltd. 

Suite 23 A-C , East Sea Business Centre 

Phase 2 , No. 618 Yan'an Eastern Road 

Shanghai, 200001 

China 

www.rs-components.com

 

 

Japan 

RS Components Ltd. 

West Tower (12th Floor),  

Yokohama Business Park, 134 Godocho, Hodogaya,  

Yokohama, Kanagawa 240-0005  

Japan 

www.rs-components.com

 

Asia 

RS Components Pte Ltd. 

31 Tech Park Crescent 

Singapore 638040 

www.rs-components.com

 

 

Europe 

RS Components Ltd. 

PO Box 99, Corby, 

Northants. NN17 9RS  

United Kingdom 

www.rs-components.com

 

 

U.S.A 

Allied Electronics 

7151 Jack Newell Blvd. S.  

Fort Worth, Texas 76118  

U.S.A.  

www.alliedelec.com

 

 

South America 

RS Componentes Limitada 

Av. Pdte. Eduardo Frei M. 6001-71 

Centro Empresas El Cortijo 

Conchali, Santiago, Chile   

www.rs-components.com

 

Summary of Contents for ICA32N

Page 1: ...INSTRUCTION MANUAL ICA32N AC DC CURRENT TRANSDUCER EN IT DE FR ICA32N...

Page 2: ...1 ICA 32N CURRENT ADAPTOR INSTRUCTION MANUAL...

Page 3: ...2...

Page 4: ...aptor for digital meters complete with coiled output cable fitted with connectors 2 Carrying case 3 Operating manual Markings on the unit Attention Follow the operating instructions Symbol for double...

Page 5: ...connectors 1 Red LED Battery voltage low 2 Green LED Power on 3 Coiled output cable Voltage output signal 4 On off and function switch Slide switch for selecting measuring function 5 Zeroing potentio...

Page 6: ...5 Fig 1...

Page 7: ...0A Accuracy A c currents at 45 to 65Hz 100A range 0 to 100A 2 2A 600A range 100 to 400A 2 2A 600A range 400 to 600A 2 5 2A Output voltage 100A range a c d c 10mV A 600A range a c d c 1mV A Output impe...

Page 8: ...torage temperature 20 to 60 C 80 RH Temperature coefficient 0 2 x specified accuracy C 18 C or 28 C Power supply One 9V battery NEDA 1604 IEC6F22 Battery life alkaline 45 hours typical Max conductor d...

Page 9: ...lative humidifies or expose it to direct sunlight 6 Before changing the battery switch the adaptor off and unplug the output connectors from the meter 7 Take the battery out if you are not going to be...

Page 10: ...ck into the input sockets of a digital multimeter and set the multimeter to an d c voltage range of 200mV or 2V 3 Adjust the zeroing potentiometer to give a reading of 0 on the multimeter display 4 Wh...

Page 11: ...10 BLACK RED Current flow Fig 2...

Page 12: ...nt face down on a work surface and unscrew the screw holding the battery cover 3 Slide the battery cover to one side and remove the battery 4 Fit a new 9V battery close the cover and screw the screw b...

Page 13: ...h Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com Asia RS Components Pte Ltd 31 Tech Park Crescent Singapore 638040 www rs components com Europ...

Reviews: