background image

the rinsing tray and in the underlying 
filter mat. 
Grease and oily dirt is rinsed into the 
base unit and is then degraded by the  
microbes into carbon dioxide and 
water. 
 
 

 

Please read the operating 
instructions for your machine 
before using it, and pay particular 
attention to the following safety 
instructions. 

Warning and information plates on 
the machine provide important 
directions for safe operation. 

In addition to the information 
contained in the operating 
instructions, all statutory safety 
and accident prevention 
regulations must be observed. 

 
 
 
 

The voltage indicated on the type 
plate must correspond to the 
voltage of the electrical source.  

Safety class 1 

– Appliances may 

only be connected to sockets with 
proper earthing. 

It is recommended that you 
connect this device to a socket 
that has a 30mARCD device to 
guard against earth leakage faults. 

Please use the mains cable fitted 
by the manufacturer; the same is 
also applicable when you replace 
the cables. 

Never touch the mains plug with 
wet hands. 

Make sure that the power cord or 
extension cables are not damaged 
by running over, pinching, 
dragging or similar. Protect the 
cable from heat, oil and sharp 
edges. 

The extension cable must have a 
conductor cross section area of 
2.5mm and be protected against 
spraying water. The connection 
must not lie in water. 

If the power cord is replaced the 
control box cover must be 
correctly refitted to ensure that it is 
water tight. 

 
 
 
 

The machine must be checked 
prior to use to ensure that it is in 

proper working order and is 
operating safely. 

The machine must not be used in 
hazardous locations. 

The appliance must be sited on 
stable ground. 

All electrical equipment in the 
working area must be protected 
against any spraying cleaning 
solution. 

Please wear appropriate safety 
gear when using the machine- 
such as safety goggles and 
protective gloves. 

Do not use the Smartwasher™ to 
clean materials containing 
asbestos or other hazardous 
substances such as pesticides. 

Only use the cleaning solutions 
approved by the manufacturer. 

If the cleaning solution comes into 
contact with the eyes, please rinse 
the eyes thoroughly with water. If 
swallowed please consult a doctor 
immediately. 

 
 
 
 

The operator must use the 
machine properly as instructed in 
this manual. The operator must 
pay attention to any surrounding 
hazards and consider those 
working around him when using 
the Smartwasher™. 

The machine should only be used 
by people who have been 
instructed in how to use it 
properly. The Smartwasher™ 
must not be operated by children. 

Never leave the machine 
unattended when the cleaning 
solution is running through the tap. 

 
 
 
Turn off the Smartwasher™ and 
unplug the connection to the electrical 
socket. Then empty the machine if you 
need to move or transport the 
Smartwasher™. Only transport when 
empty. 
 
 
 

Switch off the Smartwasher™ and 
unplug from mains socket before 
carrying out any maintenance on 
the machine. 

Please wear appropriate safety 
gear such as safety goggles and 
gloves. 

Safety Instructions 

Power Connection 

Application 

Proper Use 

Moving or Transporting 

Maintenance 

Summary of Contents for PCS25 Smartwasher

Page 1: ...PCS25 PCS28 Smartwasher Operating Manual Rozone Ltd Queen Street Darlaston Wednesbury West Midlands WS10 8JB Tel 44 0 121 526 8181 Fax 44 0 121 526 8182 E mail info rozone co uk www rozone co uk ...

Page 2: ...oil anti frost agents or similar substances enter the device this can hamper the bio degradation of oil grease by the microbes The device is not meant for cleaning painting tools The microbes are first introduced to the system in the filter mat and are then transported by the liquid cleaning solution through the filter mat into the base unit The cleaning solution in the base unit is heated by the ...

Page 3: ... The machine must be checked prior to use to ensure that it is in proper working order and is operating safely The machine must not be used in hazardous locations The appliance must be sited on stable ground All electrical equipment in the working area must be protected against any spraying cleaning solution Please wear appropriate safety gear when using the machine such as safety goggles and prot...

Page 4: ...tes correctly and safely 1 Sink Top 2 Flo Thru Brush 3 Female Valve 4 Male Valve 5 Nozzle Kit 6 False Bottom Sink Tray 7 Stainless Steel Basket Filter 8 Filter Mat with Microbes 9 Overflow Hole 10 Filter Support Grid 11 Pump On Off Switch 12 Green Power Indicator Light 13 Red Low Fluid Indicator Light 14 Fluid Level Sensor Probe 15 LED Pump 16 Pump 17 Filter 18 Heater Element 19 Power Cord 20 Base...

Page 5: ... switched off after cleaning operation is complete as this will save unnecessary loss of cleaning solution through evaporation Switch the Pump On Off switch to Off Note In order for the bioremediation process to occur the temperature of the cleaning solution must be maintained at 38 c for the microbes to operate at their optimal level Therefore the power supply to the Smartwasher must not be switc...

Page 6: ...d off and unplugged from the mains Lift off the sink top Remove dirty solution from the base unit and dispose of waste according to local authority regulations Rinse jetwash the base unit Replace sinktop checking that the hose pipes are all connected Remove sink tray Place new filter mat on filter support grid blue side down white side up Replace sink tray Pour 80 litres of new cleaning solution i...

Page 7: ... any way without prior approval Product Machine designed for Partscleaning using water based cleaning solutions Type PCS25 Smartwasher PCS28 Supersink Smartwasher Relevant 2006 95 EC EU Directives 2004 108 EC Applied EN55014 1 2006 Harmonized EN55014 2 1997 A1 2001 Standards EN12921 1 EN12921 2 EN60335 1 EN61000 3 2 2000 A2 2005 EN61000 3 3 1995 A1 2001 A2 2005 Applied National Standards The under...

Page 8: ...uid Closed tap on both nozzle and brush Open taps Operator Insufficient cleaning solution in the tank Add fluid until the red indicator light goes off Operator 10 minute pump timer has expired Flick the ON OFF switch off and on to restart flow Operator Pump has failed Replace the pump Service Engineer Hose is blocked or has become disconnected Check hose connection from the pump to the nozzle or t...

Page 9: ...the P A T tester onto the heater element and take readings as normal use the 25amp setting for this test The heater effectively earths the fluid in the base of the machine A 500v Insulation test should not be carried out on this machine due to the electronic nature of the control circuit board This is with reference to the codes of practice Sections 8 1 3b and 15 3b This test may be carried out in...