background image

   

Page 10

Summary of Contents for SUPER FERRONA 16 MKII

Page 1: ...PER FERRONA 16 MKII USERS Pages 2 3 INSTALLATION Pages 4 6 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 2: ...Super Ferrona 16 MKII is a decorative fuel effect appliance designed and manufactured to the requirements of the British Standards Institution BS 5258 Part 12 1990 and is for use on Natural Gas only All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordanc...

Page 3: ... UP THE COAL BED See the identification sheet on page 8 Components 2 burner inserts 16 Large Coals Coal support shelves L R hand 4 Medium Coals Artificial coal front 2 Triangular Coals Place the left and right coal support shelves with the rebate on the underside over the rear flange of the support channel Place the two Tee shaped burner inserts into the channel between the front and rear ports of...

Page 4: ...e materials close to the hearth The width must be a minimum of 150mm either side of the fireplace opening and a depth of 300mm from the front face of the opening Purpose built superimposed fire resisting hearths and back panels specified as suitable by the manufacturer may be used If hearths or back panels are not suitable for solid fuel they should have been clearly marked Not suitable for solid ...

Page 5: ...er the left or right in 8 mm diameter pipe if a right hand connection is required the tube should be routed across the front of the fascia panel by rotating the inlet elbow to the required position See fig 4 A suitable isolating cock or restrictor elbow should be fitted close to the appliance to facilitate servicing TO CHECK THE APPLIANCE SETTING PRESSURE The pressure test point at the inlet elbow...

Page 6: ...The test should be repeated if an extractor fan or fan powered flue appliance is fitted to the room If there is a connected room with an extractor fan the test should be repeated with all the connecting doors to that room opened Demonstrate the lighting and extinguishing procedures ADVISE THAT The curing effect of heating the coals will cause an initial odour these are not harmful although additio...

Page 7: ...to components below the burner assembly it has to be removed from the case by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the fascia panel Where the supply is fed from the right hand side across the front of the fire it will be necessary to disconnect the supply from the isolation tap elbow i TO CLEAN OR REPLACE THE INJECTOR Unscrew the compression ...

Page 8: ...ESCRIPTION CROSSLEE No GC No Piezo Igniter 40245 397 686 Control Knob 40232 170 014 Control Valve 41833 386 147 Oxy Pilot Burner Assembly SIT 42313 Main Injector Bray Cat 82 460 41669 379 871 Or Stereomatic 41670 Coal Support Shelf 42889 Front Coal mould 40481 170 248 Set of Coals 42893 ...

Page 9: ...Page 8 ...

Page 10: ...Page 9 ...

Page 11: ...Page 10 ...

Page 12: ...Page 11 ...

Page 13: ...actured by CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 5EX Spares Tel 01422 203963 Fax 01422 204475 Service GSA Ltd 01703 516611 Customer Service 01422 200660 Fax 01422 206304 Technical Help Line 0906 8633268 Calls charged at 60p per minute ...

Reviews: