THE FOLLOWING SECTION LISTS THE INSTALLATION REQUIREMENTS AND REGULATIONS
The relevant Codes of Practice and British Standards are: -
BS 5440
Part 1 1990
The Building Regulations issued
BS 5440
Part 2 1989
by the Department of the Environment.
BS 6461
Part 1 1984
BS 5871
Part 3 1991
The Building Standards (Scotland)
BS 6891
1988
(Consolidation) Regulations issued
BS 8303
1994
by the Scottish Development Department.
BS 1251
1987
In particular: -
The fireplace and chimney or flue must comply with the requirements of BS 8303 1986 & BS6461 Part 1 1984.
The effective flue height must be a minimum of 3 metres and should be of 225mm x 225mm brick, stone or a lined
chimney with a minimum diameter of 175mm.
Any permanent flue restriction must be removed and any variable dampers locked fully open or removed. The
chimney flue must be swept prior to installation unless new and the gas installation must use rigid or semi-rigid
tube.
A non-combustible hearth with a minimum thickness of 12.5mm and having a perimeter of 50mm above floor level
is required to discourage placing carpets or combustible materials close to the hearth. The width must be a minimum
of 150mm either side of the fireplace opening and a depth of 300mm from the front face of the opening.
Purpose built superimposed fire resisting hearths and back panels, specified as suitable by the manufacturer may be
used. If hearths or back panels are not suitable for solid fuel, they should have been clearly marked, ‘Not suitable for
solid fuels.’
TECHNICAL DATA
Height
295mm
Type of Gas
G20 (NG) only
Width
350mm
Max Heat Input (Gross)
6.6kW - 22520 Btu/h
Depth
260mm
Min Heat Input (Gross)
3.83kW -13070 Btu/h
Overall depth
Supply Setting pressure
/- 1mbar (cold)
(Mach II) inc. F&F
310mm
(JB)
330mm
See fig 2. for the sizes of fireplace opening
Injector
Stereomatic
046.19.196.076
Or Bray Cat 82/460
Gas valve
Isphording GH379 001 003 00A
Or Thermaco 21018B
Pilot Assembly
SIT Oxy-pilot assembly NG9022
Or Concentric ODS1
Note. None of the materials used in the manufacture of this appliance contain asbestos.
INSTALLING THE APPLIANCE
When an existing refractory fire back (chairbrick) is fitted, care must be taken to ensure that the depth of the
opening is no less than 205mm from the front face of the surround to the front face of the chairbrick. This is to
ensure that no luminous flame extends beyond the front face of the opening. See fig. 2.