background image

Page 6

MAINTENANCE AND SERVICING

GENERAL

A.

REMOVAL OF DEBRIS or SOOT DEPOSIT

Allow the appliance to cool for two to three hours before removing all of the coals and ceramic blocks for cleaning
purposes. Once all the ceramics are removed from the fire bed check that no debris is located in the burner slots
(both front & rear).  If any debris is present it may easily be removed by using a small piece of thin cardboard to
ease out any foreign matter. Be sure to remove the cardboard after use. To ensure that the release of fibres from
these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA
filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire.
When replacing these articles we recommend that the replaced items are not broken up, but are sealed within heavy
duty polythene bags, clearly labelled as RCF waste. This is not classified as "hazardous waste" and may be disposed
of at a tipping site licensed for the disposal of industrial waste. Protective clothing is not required when handling
these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the
work area and always wash your hands before eating or drinking. Any sooty deposit on the thermocouple probe can
be cleaned off using a non-fluffy cloth.

* DO NOT USE ABRASIVE MATERIALS *

B.

SERVICING COMPONENTS BELOW THE BURNER ASSEMBLY

Remove coals, coal supports, burner inserts and front simulated coal.  To gain access to components below the
burner assembly it has to be removed from the case by disconnecting the gas supply at the inlet elbow and
unscrewing the two screws at the base of the fascia panel. Where the supply is fed from the right hand side across
the front of the fire, it will be necessary to disconnect the supply from the isolation tap/elbow.

i) TO CLEAN OR REPLACE THE INJECTOR: Unscrew the compression nut connecting the gas supply to the
elbow injector while supporting the injector. This is to prevent distortion of the framework, unscrew and remove the
gas supply tube from the gas control valve, hold the injector lock nut with a spanner and rotate the injector. Replace
in reverse order.

ii) TO REPLACE THE GAS CONTROL VALVE: Disconnect the three gas pipes and the thermocouple from the
control.  Pull off the knob and lay to one side.  Undo the retaining nut at the front of the tap niting position to
withdraw the control from the mounting bracket. Replace in reverse order.

iii) TO REPLACE THE PIEZO IGNITER: Pull off the HT lead from the rear of the igniter.  Retain the metal fixing
nut with one finger and rotate the body of the igniter to unscrew.  Withdraw the igniter from the front.  Replace in
reverse order and reconnect the HT lead.

iv) TO CLEAN OR REPLACE THE OXY-PILOT ASSEMBLY (including electrode and thermocouple): Unscrew
the self -tap screw securing the clamp bracket. Undo the supply tube nut at the gas connection to the pilot; withdraw
the Oxy-pilot assembly.  Clean off any lint or fluff taking care to avoid damage. The individual parts cannot be
changed separately as the assembly is precision built. Reassemble in reverse order. It is advisable to check joints for
leaks prior to refitting the burner unit into position.

Summary of Contents for SUPER FERRONA 16 MKII

Page 1: ...PER FERRONA 16 MKII USERS Pages 2 3 INSTALLATION Pages 4 6 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 2: ...Super Ferrona 16 MKII is a decorative fuel effect appliance designed and manufactured to the requirements of the British Standards Institution BS 5258 Part 12 1990 and is for use on Natural Gas only All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordanc...

Page 3: ... UP THE COAL BED See the identification sheet on page 8 Components 2 burner inserts 16 Large Coals Coal support shelves L R hand 4 Medium Coals Artificial coal front 2 Triangular Coals Place the left and right coal support shelves with the rebate on the underside over the rear flange of the support channel Place the two Tee shaped burner inserts into the channel between the front and rear ports of...

Page 4: ...e materials close to the hearth The width must be a minimum of 150mm either side of the fireplace opening and a depth of 300mm from the front face of the opening Purpose built superimposed fire resisting hearths and back panels specified as suitable by the manufacturer may be used If hearths or back panels are not suitable for solid fuel they should have been clearly marked Not suitable for solid ...

Page 5: ...er the left or right in 8 mm diameter pipe if a right hand connection is required the tube should be routed across the front of the fascia panel by rotating the inlet elbow to the required position See fig 4 A suitable isolating cock or restrictor elbow should be fitted close to the appliance to facilitate servicing TO CHECK THE APPLIANCE SETTING PRESSURE The pressure test point at the inlet elbow...

Page 6: ...The test should be repeated if an extractor fan or fan powered flue appliance is fitted to the room If there is a connected room with an extractor fan the test should be repeated with all the connecting doors to that room opened Demonstrate the lighting and extinguishing procedures ADVISE THAT The curing effect of heating the coals will cause an initial odour these are not harmful although additio...

Page 7: ...to components below the burner assembly it has to be removed from the case by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the fascia panel Where the supply is fed from the right hand side across the front of the fire it will be necessary to disconnect the supply from the isolation tap elbow i TO CLEAN OR REPLACE THE INJECTOR Unscrew the compression ...

Page 8: ...ESCRIPTION CROSSLEE No GC No Piezo Igniter 40245 397 686 Control Knob 40232 170 014 Control Valve 41833 386 147 Oxy Pilot Burner Assembly SIT 42313 Main Injector Bray Cat 82 460 41669 379 871 Or Stereomatic 41670 Coal Support Shelf 42889 Front Coal mould 40481 170 248 Set of Coals 42893 ...

Page 9: ...Page 8 ...

Page 10: ...Page 9 ...

Page 11: ...Page 10 ...

Page 12: ...Page 11 ...

Page 13: ...actured by CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 5EX Spares Tel 01422 203963 Fax 01422 204475 Service GSA Ltd 01703 516611 Customer Service 01422 200660 Fax 01422 206304 Technical Help Line 0906 8633268 Calls charged at 60p per minute ...