This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning
appearance with the instant control and convenience of gas. The fire has been constructed to enable it to be
installed into applications where the warmth and comfort of an open fire and high radiant heat is required. This
appliance is intended for decorative purposes, the coal bed uses ceramic simulated coals to give a realistic
appearance and to allow secondary air to be entrained into the bed to ensure clean combustion. An aerated single
port steel burner is used running parallel across the front of the fire. A single gas control with a variable high to
low setting is used with a Flame Supervision Device (FSD).  This is fitted to ensure that should the pilot flame be
extinguished for any reason,  (including turning off the appliance), the gas supply to the burner is cut off until a
full lighting sequence is repeated. A separate Piezo igniter is used to ignite an Oxy/Pilot sensor (ODS) which will
cause the appliance to ’shut off’ in the event of continued spillage occurring under hazardous or blocked flue
conditions. The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning
purposes when required. It is important when relaying the coal bed and coals to follow the instructions correctly.

TECHNICAL DATA 

TYPE OF GAS

G31 only

SETTING PRESSURE

37 mbar +/- 1 mbar (cold)

GAS INPUTS (Gross) 

Max 6 kW  (20470  Btu/h)

Min 3.5 kW  (11940  Btu/h)
Pilot 0.26 kW  (890    Btu/h)

IMPORTANT NOTES

This appliance is intended for decorative purposes, it is designed and manufactured to the requirements of the BS
5258 Pt 16: 1991 and is for use on Propane Gas Only.

All gas appliance installations must be carried out by a competent person in accordance with the Gas Safety
(installation & Use) Regulations 1994 (as amended) or the rules in force and in accordance with the Manufacturers
Installation Instructions. Failure to comply could lead to prosecution.

The chimney or flue (unless new) must be swept before installation. It is recommended that the appliance be
serviced annually by a competent person and that the flue is checked for satisfactory clearance of products and
there is no excessive build up of soot. The curing effect of heating the coals will cause an initial odour which,
although not harmful, may require additional ventilation until the odour has disappeared.

Ventilation is required for this appliance with a minimum cross sectional area of 100 sq. cms and should be
checked regularly to ensure that it is free from obstruction.

 The appliance has a naked flame, a fireguard conforming to BS 6539 or BS 6778 should be used for the
protection of the very young, elderly and infirm. Combustible materials should not be put on or left in the hearth
nor should the coal bed be used to burn rubbish or other materials.

Care must be taken on the selection of wall coverings within close proximity of the fire as some vinyl and
embossed materials may be become discoloured by convected heat. Soft furnishings must be kept clear from the
radiant heat of the fire and from impinging the hearth area. The hearth must not be covered by any combustible
materials such as carpets etc.

This product uses fuel effect pieces, gaskets and insulation material containing Refractory Ceramic Fibre
(RCF), which are man-made vitreous silicate fibres. Excessive  exposure to these materials may cause
temporary irritation to eyes, skin and respiratory tract, consequently, it makes sense to take care when handling
these articles to ensure that the release of dust is kept to a minimum.

This fire will run for 2.2 hours on one kilogram of gas with the gas control on the high setting.

Page 2

Summary of Contents for G31

Page 1: ...0102 095 50261 6 0 1 67 1 5 USERS INSTRUCTIONS THIS CAT I3P APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION ...

Page 2: ...petent person in accordance with the Gas Safety installation Use Regulations 1994 as amended or the rules in force and in accordance with the Manufacturers Installation Instructions Failure to comply could lead to prosecution The chimney or flue unless new must be swept before installation It is recommended that the appliance be serviced annually by a competent person and that the flue is checked ...

Page 3: ...t flame remains lit Refer to Fig 2 to view pilot Note For convenience the unit can be operated with the pilot only i e with the control knob set in the IGN position Push in the gas control slightly and turn anti clockwise so that the indicator dot is at the required setting Replace the fret controls cover To turn off the appliance and pilot turn the gas control clockwise from any position until th...

Page 4: ... 5 small round coals between the gaps formed in the coals laid in 1 2 above Fig 4 Cleaning the Front of the Appliance The fire must be turned off and allowed to cool The paintwork should be cleaned with a soft cloth or soapy water the brass trim has a clear lacquer coating to preserve the polished finish Spares and Service For spares and service contact your local supplier installer or direct to t...

Page 5: ...Page 4 Page 5 ...

Page 6: ...ddress __________________________________________________ __________________________________________________ Date of Purchase__________________________________________________ Serial Number __________________________________________________ Please return this section with any components that are faulty under guarantee MAXIMUM HEAT INPUT 6 kW 20470 Btu h Gross Royal Cozyfires are manufactured by CR...

Page 7: ...0102 095 50251 6 0 1 67 1 5 INSTALLATION and SERVICING INSTRUCTIONS THIS CAT I3P APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 8: ...an Oxy pilot sensor O D S that will cause the appliance to shut off in the event of continued spillage occurring under hazardous or blocked flue conditions The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required It is important when relaying the coal bed and coals to follow the instructions correctly This appliance is suitable for i...

Page 9: ...a minimum open area in the fret of 20 sq cms and 60 sq cms in the front Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e g many embossed vinyl wall coverings may become discoloured if located too close to the appliance Clearances required for combustible shelves are shown in fig 1 Care should be taken to ensure that when the appliance is installed ...

Page 10: ... incorrect flue terminals must not restrict any of the above flues The flue must only service a single appliance and not have any branches or traps that may impede the natural draught Any flue damper plate or restrictors shall be removed or fixed in the fully opened positions The front and base of the fire opening must be flat and square to ensure a good seal with the appliance this is to ensure t...

Page 11: ...d tube such as bundy suitable pieces of bundy are included in the fitting kit to assist the installer Where a concealed gas supply is used the installer is reminded of the requirements of BS 6891 1988 dealing with enclosed pipes The Standard requires that when a gas pipe is fed through a wall the pipe should be enclosed in a tight sleeve to protect against failure caused by movement and shall be c...

Page 12: ...coating from the brass finish Laying the Coal Bed Fit the coal support shelf ensuring that the front edge sits behind the three tabs and the simulated coal front Fig 10 Referring to figures 10 11 12 and 13 lay the coals as follows 1 Place 4 large round coals between the simulated coal front and the support shelf Fig 12 2 Place 3 round coals between the gaps in the front row Fig 12 3 Place the 5 sm...

Page 13: ...s will cause an initial odour which although not harmful may require additional ventilation until the odour has disappeared Any debris or soot is cleaned from the appliance Advise the customer that they should read their Users Instructions before operating the fire and always follow the advice in the section headed Removal of Debris or Soot Deposits The appliance must be serviced annually by a com...

Page 14: ... below the burner assembly it has to be removed from the vent box case by disconnecting the gas supply at the inlet elbow and unscrewing the two screws on the sides of the facia panel Where the supply is fed from the right hand side across the front of the fire it will be necessary to disconnect the supply from the isolation tap elbow i TO CLEAN OR REPLACE THE INJECTOR Remove the aeration sleeve r...

Page 15: ...Page 9 ...

Page 16: ...Page 10 ...

Page 17: ...Page 11 ...

Page 18: ......

Page 19: ...Page 12 ...

Page 20: ...Page 13 ...

Page 21: ...Page 14 No Figures 13 15 On this page ...

Page 22: ...omponents that fail under guarantee Maximum Heat Input 6 kW 20470 Btu h Gross Royal Cozyfires are manufactured by CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 5EX Spares Tel 01422 203963 Fax 01422 204475 Service GSA Ltd 01703 516611 Customer Service 01422 200660 Fax 01422 206304 Technical Help Line 0906 8633268 Calls charged at 50p per minute ...

Reviews: