Important information - retain for future reference

Shiplap buildings come ready stained but this is only a preparatory treatment. To VALIDATE the guarantee, the building must be properly treated with a  recognised external 

wood preserver WITHIN 3 MONTHS of assembly and RE-TREATED ANNUALLY  thereafter. The building must also be erected on 50mm x 50mm treated wooden or 

similar bearers (These are not supplied with the kit.) Ground contact must be avoided.

Timber Information.

As timber is a natural material, there are certain weather conditions that may affect the materials properties. In times of excessive dry spells the material may lose some of its 

internal moisture causing a certain degree of shrinkage on a panel and in periods of excessive rain there will be a certain amount of swelling throughout the wooden panels. 

This process can not be avoided. If you have problems with certain boards shrinking in dry spells try to decrease the amount of direct sunlight on the building or the amount 

of air passing over the building. During hot spells spray water directly onto the panels with the aid of a garden hose.

If in doubt of any aspect regarding the assembly, use or safety of your Garden Bar please contact us:

Help Line: (Normal Office Hours)  01829 261 121
Email: [email protected]

ROWLINSON GARDEN PRODUCTS LIMITED

Green Lane

Wardle Nr. Nantwich

Cheshire

CW5 6BN

www.rowgar.co.uk

We constantly improve the quality of our products, 

occasionally the components may differ from the 

components shown and are only correct at time 

of printing. We reserve the right to change the 

specification of our products without prior notice.

2019 © Rowlinson Garden Products Ltd

11. Coverstrips

In to each corner of the plain wall side fit a plain wall coverstrip. Attach each one using 3 x 30mm nails. Position the third plain wall coverstrip centrally over the join of the 

two plain panels and secure in place with 3 x 30mm nails. To the hatch side of the building under the bar shelf, fit the hatch side lower coverstrips using 3 x 30mm nails per 

coverstrip. One in each corner of the building and the third over the join of the two hatch panels. Above the shelf fit a hatch side mid coverstrip to the panel framing in the 

corners using 3 x30mm nails per coverstrip. Above the mid coverstrips secure a hatch panel upper coverstrip using 2 x 30mm nails. Fit the hatch centre coverstrip over the 

join of the two hatch panels using 3x 30mm nails.

12. Bargeboards, finials & hatch covers

Attach bargeboards at the front so that the top edge is flush with the roof line and the two boards meet evenly in the middle, secure using 3 x 30mm nails per board. Position 

a finial centrally over the join of the two bargeboards and fix in place using 2 x 30mm nails. Attach the Bargeboards and finials to the back of the building in the same way.
Fit four turn buttons to vertical frames of the hatch covers using 1 x 25mm screw per turn button. Position them approximately 60mm from the top and bottom of the 

frames. Once the turn buttons are fitted, the hatch covers can be positioned in the hatch panel opeings and secured by turning the turn buttons horizontally. 

60mm

30mm

30mm

30mm

30mm

30mm

30mm

30mm

25mm