www.rovingnetworks.com
Version 1.0r 9/21/2012
85
RN -W IFLYCR -U M
BOOT-UP TIMING VALUES
Table 31 shows the boot-up timing values.
Table 31. Boot-Up Timing Values
Function
Description
Time (ms)
Power up
Power up time from reset high or power good to boot code loaded.
70
Initialization
Initialize ECOS.
50
Ready
Load configuration and Initialize application
30
Join
Associate using channel = 0 (full channel scan, mask = 0x1FFF).
80
Associate using channel = 0 (primary channel scan, mask = 0x421).
15
Associate using channel = X (fixed channel).
5 - 20
Authentication
Authenticate using WPA1 or WPA2 (highly dependent on access point response).
50 - 250
Aquire IP
DHCP obtain IP address (highly dependent on DHCP server response time).
AP dependent