show q <
value
>
This command displays the value of the analog interface pin, where <
value
> is 0 to 7. The A/D reading is 14 bits with
a range of 0 to 400 mV (therefore, the resolution is 24 uV). The output is in uV (1,000 millivolts). The module returns
a value in the format 8
xxxxx
, where
xxxxx
is the voltage in microvolts sampled on the channel you requested.
NOTE:
If a web post or UDP broadcast samples the data, the data is shifted as described in “UDP Broadcast”
on page 62.
Example:
show q 0
// Show the voltage on channel 0
show q 0x1<
mask
>
This command displays multiple analog interface values simultaneously, where <
mask
> is a bit-mask representing the
channels. For example, to read channels 0, 1, and 7, use the command:
show q 0x183
The module returns 8<
chan0
>, 8<
chan1
>, 8<
chan7
>
NOTE:
If a web post or UDP broadcast samples the data, the data is shifted as described in “UDP Broadcast”
on page 62.
Example:
show q 0x183
// Show values for channel 0, 1, and 7
show rssi
This command displays the last received signal strength.
Example:
show rssi
// Show signal strength
show stats
This command displays the current statistics, packet RX/TX counters, etc.
Example:
show stats
// Show the statistics
show time
This command displays the number of seconds since the module was last powered up or rebooted.
Example:
show time