background image

11

Touch the center of the squares that appear 

in the corners of the screen,  

repeat four times for every squares.

NOTE

use the pen and touch the the screen 

exactly in the center of the circle.  if you do not 

carry out this procedure correctly the touch 

commands may be inaccurate.

TOUCHSCREEN CALIBRATION

 _____________________________

Touch “CONFIGURATION MENU”  

from the volume window;

Touch “METER”  

then “CALIBRATE TOUCHSCREEN”;

if the touchscreen does not respond to the commands, it may be necessary to calibrate:

Summary of Contents for HD TAB 900

Page 1: ...TAB 900 TAB 900 TAB 900 TAB 900 HD HD HD HD www roverinstruments com TAB 900 Plus TAB 900 Plus TAB 900 Plus TAB 900 Plus TFT 16 10 TFT 16 10 USER S GUIDE...

Page 2: ...T HARDWARE RESET SOFTWARE With instrument ON Keep the HOME key pressed for 10 and turn on again From instrument OFF Switch on the meter immediately after keep the VOLUME key pressed until a beep is he...

Page 3: ...J45 2 HDMI Output 3 USB B SW upgrades 4 USB A memory stick 5 Power Supply input 12 V DC 2A 6 Fan 7 Analog video IN CVBS 8 Remote Power Supply switch DC at RF IN ON OFF 9 IF RF IN F 75 10 OPTIC IN SC o...

Page 4: ...he practical ring belt with quick attachment If you change the configuration of the shoulder strap you can easily carry the meter vertically by your side You can also carry your instrument using its p...

Page 5: ...screen and to change values DISPLAY ZONES 1 tuning parameters 2 live picture 3 measurements 4 channel info 5 transport stream info 6 context sensitive menu How to select from the menus and adjust the...

Page 6: ...the numerical keyboard Rotate the wheel and select frequency FREQ fig 1 Keep the wheel pressed for 2 to visualize the keyboard fig 2 Press the relative number keys to digit the frequency value require...

Page 7: ...AVIGATION USING MIXED COMMANDS MECHANICAL TOUCH fig 5 fig 4 fig 3 Select from the menus and adjust the value using the drop down menu Touch a value in the menu to visualize the drop down menu fig 1 Ro...

Page 8: ...8 O R O R Example of SATELLITE transponder selection TP TS O R O R fig 2 fig 3 fig 1 fig 2 fig 3...

Page 9: ...g the numerical keyboard Touch FREQ to show the menu INSERT FREQ fig 1 Touch the numbers to digit the required frequency value fig 2 Finally touch enter and confirm the selection fig 3 Example of manu...

Page 10: ...nutes the meter automatically turns off press any key to temporarily reset the battery save mode Touch CONFIGURATION MENU then METER in the volume screen and set the TIMER OFF value required The meter...

Page 11: ...en exactly in the center of the circle if you do not carry out this procedure correctly the touch commands may be inaccurate TOUCHSCREEN CALIBRATION______________________________ Touch CONFIGURATION M...

Page 12: ...tuned TV channel in the TV master PLAN Touch TV and then DISCOVERY and set the identification mode TERR ONLY TERR CABLE Touch CATV and then DISCOVERY and set the identification mode CABLE ONLY TERR C...

Page 13: ...r red marker and the noise level estimated in the guard band 1 282 MHz from the video carrier white marker Touch CONFIGURATION MENU from the volume screen Touch TV then C N TYPE C N measurement mode I...

Page 14: ...s the SPECT 4 Screenshot key for 4 seconds keys and wait for file to be saved the instrument will make a series of beeps Digit the file name and touch ENTER N B If the memory is not inserted correctly...

Page 15: ...r to obtain the Satellite list Touch directly the desided satellite or use the encoder At the end touch MEAS to make the measure or SPECT for visualize the spectrum NOTE The chosen Satellite and Trans...

Page 16: ...________ DVB S DVB S2 S2M SAT MEASURES________________ Press the HOME key Main measures and image Touch SAT and then MEAS PICT or use the encoder Press repeatedly to navigate into SAT measures screens...

Page 17: ..._____________________________ NIT INFO VISUALIZATION referring to an HOTBIRD 13 East transponder Touch VISUALIZE NIT Touch MENU from the MAIN MEASUREMENTS PICTURES Example 1 NOTE The function VISUALIZ...

Page 18: ...lative file name File name The weekly application of SW CHANNEL MONITOR allow you to controll and register the trend of the main parameters of a digital signal over time from 30 minutes to one week TV...

Page 19: ...___________________________________________ Touch MENU on the main measurements and picture screen Touch CONFIGURATION MENU in the volume window Select the PLS required and set the parameters Touch IS...

Page 20: ...hen SPECT or use the encoder SAT spectrum SPAN FULL EXT from 230 to 2610 MHz with universal LNB SAT spectrum SPAN FULL EXT from 230 to 2610 MHz with LNB WIDE BAND Example 2 Example 1 Touch SPAN and ro...

Page 21: ...y select RBW filter in SAT mode The RBW Resolution Bandwidth filter function determines the bandwidth of the bandpass filter which is used to generate the spectrum of the input signal IF This bandpass...

Page 22: ...reach the wanted satellite EXAMPLE 1 EXAMPLE 2 The satellite you have pointed is not correct the lower part of the display shows the following information EUTE 16 G0 WEST move the satellite dish west...

Page 23: ...EXAMPLE 3 SAT to be found SAT detected IMPORTANT The text messages that from time to time will appear on the screen of the instrument when moving the satellite dish to east or west are bounded to the...

Page 24: ...______________ Press the HOME key Touch SAT and then CONST or use the encoder Touch FULL and select the zone of constellation to elnarge QPSK constellation 8PSK constellation Example 2 Example 1 Press...

Page 25: ...heck the quality of 4 transponders simultaneity and to check the operation of the 4 LNB polarities If the chosen satellite is found the buzzer will start if this does not happen continue looking for t...

Page 26: ...ample 13 0 EAST Touch COUNTRY and select your Nation for example Italy Touch CITY and select your city for example Roma Touch COMPUTE to obtain the automatic calculation of pointing parameters Azimuth...

Page 27: ...ode to perform a verify of the 8 exit frequencies user 1 4 from LNB multiswitch MEASURES WITH SCR LNB MULTISWITCH___________ Touch LNB TYPE and select the installed LNB multiswitch model see NOTE Touc...

Page 28: ...de to perform a verify of the 8 exit frequencies user 5 16 from LNB multiswitch LNB MULTISWITCH dCSS MEASURES_________________ Touch LNB TYPE and select the installed LNB multiswitch model see NOTE To...

Page 29: ...rvice list Touch the image to enlarge Touch again to come back at the service list RADIO TV service selection Press HOME key Touch SAT and then MPEG ou use the encoder Touch directly the RADIO TV desi...

Page 30: ...list Touch directly the desided canalization or use the encoder At the end touch MEAS to make the measure or SPECT for visualize the spectrum TV TV TV MEASURE TV TV o r NOTE The chosen canalization a...

Page 31: ...________ Press the HOME key Main menu and image Touch TV and then MEAS PICT or use the encoder Press to enter in the spectrum DIGITAL TV MEASUREMENT DISPLAYS DVB T DVB T2 M PLP Press repeatedly to nav...

Page 32: ...__ DVB T2 SIGNAL PROFILE SELECTION__________________________ Touch MENU from MAIN MEASURES IMAGES screen Touch MENU from MAIN MEASURES IMAGES screen Touch PLP and select the desired PLP transport Stre...

Page 33: ...SPECT or use the encoder TV SPAN FULL spectrum from 5 to 1 250 MHz TV SPAN FULL spectrum with mixed channels SAT signals from 5 to 1 250 MHz Example 2 Example 1 Touch SPAN and rotate the encoder to s...

Page 34: ...oder Touch FULL and select the box of constellation to enlarge Constellation DVB T Constellation DVB T2 Example 2 Example 1 RELATED FUNCTIONS__________________________________________ Press to enter i...

Page 35: ...w to make analysis of the trend MER for single COFDM carriers which make up a signal DVB T or DVB T2 Press the HOME key Touch TV and then MER vs CARRIER or use the encoder Touch MENU to obtain differe...

Page 36: ...ion mode VIS TYPE REVERSE PICTURE FULL MER vs CARRIER visualization mode VIS TYPE NORMAL PICTURE FULL START STOP CARR from 3000 to 4000 RELATED FUNCTIONS__________________________________________ Pres...

Page 37: ...n touch the Marker and rotate the encoder to select the ECHOES MICROECHOES VISUALIZATION_________________________________ Touch TYPE and select the echoes visualization mode DISTANCE or TIME Impulse r...

Page 38: ...time ROVER meters allow you to see ECHOES measure the power and the delay in uS and the distance of the interfering broadcaster in Km There are currently very few meters that allow you to measure ECH...

Page 39: ...MPEG service list Touch the image to enlarge Touch again to come back at the service list RADIO TV service selection Press HOME key Press repeatedly to navigate into TV measures screens Measures Cons...

Page 40: ...MONITOR or use the encoder The weekly application of SW CHANNEL MONITOR allow you to controll and register the trend of the main parameters of a digital signal over time from 30 minutes to one week TV...

Page 41: ...ist Touch directly the desided canalization or use the encoder At the end touch MEAS to make the measure or SPECT for visualize the spectrum NOTE The chosen canalization and channel will remain in mem...

Page 42: ...HOME key Main measures and image Touch CATV and then MEAS PICT or use the encoder RELATED FUNCTIONS__________________________________________ Press repeatedly to navigate into CATV measures screens M...

Page 43: ...ATV spectrum SPAN 10 MHz CATV spectrum SPAN VHF Example 2 Example 1 Press again te spectrum key to activate the MAX HOLD function Touch SPAN and rotate the encoder to select the desired SPAN value 1 2...

Page 44: ...ion Example 2 Example 1 RELATED FUNCTIONS__________________________________________ CONSTELLATION ANALYSIS________________________________ Touch FULL and select the box of constellation to enlarge Pre...

Page 45: ...___________________________________________________ Press the HOME key Touch CATV and then LEAKAGE or use the encoder Set the desired parameters at the end touch START to start the leakage measures Le...

Page 46: ...__________________________________________________ Press the HOME key Touch CATV and then LEAKAGE or use the encoder Ingress measures Set the desired parameters at the end touch START to start the Ing...

Page 47: ...CHOICE___________ Images and MPEG service list Touch the image to enlarge Touch again to come back at the service list RADIO TV service selection Press repeatedly to navigate into CATV measures screen...

Page 48: ...lication is indicated to resolv the reception problems which occur occasionally it allow you also to measure memorize and visualize local or in remote the digital signals parameters tested DVB S T C P...

Page 49: ...TV SPECTRUM_______________________________________________________ CATV SPECTRUM___________________________________________________ After selecting the desired Operation Mode TV CATV or SAT you can d...

Page 50: ...and memorizes the measured optical power value Optic Ref for Example 4 51 dBm Touch DC RF and if required select the power supply voltage for Example 12V In the OPTIC POWER LOSS field the optical att...

Page 51: ...tical mode you can measure the spectrum and measure just on Low Band Vertical Transponders VL Main measures and image OPTICAL INPUT RF MEASURES Press the HOME key Touch OPTIC and then MEAS PICT or use...

Page 52: ...possible to analyze the spectrum and measure only vertical low band VL transponders FIBER OPTIC AND REMOTE POWER SUPPLY CABLE CONNECTION SAT spectrum SPAN Full EXT from 230 to 2610 MHz SAT spectrum SP...

Page 53: ...imum level of the received signal memorized Touch CHAN to select channels reception modalities all or from 1 to 13 for 2 4 GHz networks and from 36 to 165 for 5 GHz networks WI FI ANALYZER opt WI FI W...

Page 54: ...ized channels and distinguishes Analog and Digital signals using 2 different colours Standard BARSCAN TV canalization Press the HOME key then touch BARSCAN Touch MENU to choose the bargraph mode LEVEL...

Page 55: ...will be overwritten wait a few mins the meter indicates the recorded ANALOG DIGITAL CHannels MEMORY Set the desired parameters Touch to FILE N and select the destination file AUTO where the search mus...

Page 56: ...56 Once the Automemory is completed the AUTO plan is automatically selected Search channels complete Search channels in progress...

Page 57: ...ALL to recall the Logger or EXIT to exit Touch SPECIAL FUNCT and then SAVE DATALOGGER DATA LOGGER run Example of saved measured in the Log file Touch the screen to browse through measurements saved in...

Page 58: ...__________ Press the HOME key Touch RECALL DATALOGGER and Set the LOG file parameters Touch RECALL to see them Touch SPECIAL FUNCT and then RECALL DATALOGGER Example of saved measured in the Log file...

Page 59: ...rams the STOP GO function will assist when running a LOGGER asking to move the cable lead from a TV to a SAT signal source Touch SAVE DATALOGGER and set the parameters required Touch START SAVE to cre...

Page 60: ...____________ Press the HOME key Touch SPECIAL FUNCT and then RECALL DATALOGGER Touch RECALL DATALOGGER and Set the LOG file parameters Touch RECALL to see them Example of saved measured in the Log fil...

Page 61: ...pedance matching of a 75 distribution installation Through the use of calibrated noise generator for Example ROVER mod CNG 90 STC CNG 70 USB if in a distribution installation there was an impedance mi...

Page 62: ...alue example 1 5 m Example 1 Example 2 Touch SPAN and select the correct visualization value Touch VERT POS and select the correct visualization value Touch MRK1 freq then MRK2 freq and set the marker...

Page 63: ...stable TYPE Type of cable to be tested AIRSPACE coaxial cable with dielectric in the air COMPACT coaxial cable with compact dielectric FOAM coaxial cable with foam dialectric V O P Propagation speed S...

Page 64: ...N Buzzer Graphic of the progress of the noise NOISE MARGIN of the tuned channel according to time high tones the BEST Noise Margin level deep tones the WORST noise margin level Noise Marg real time no...

Page 65: ...S NO filter required No interference detected High LTE interference The lower part of the display shows the following information FAIL 20dB ATTEN SUGGESTED the instrument suggests attenuating the inte...

Page 66: ...n touch BUZZ NOIS MARGIN BUZZER NOISE MARGIN GRAPH______________________________ Buzzer Graphic of the progress of the noise NOISE MARGIN of the tuned channel according to time high tones the BEST Noi...

Page 67: ...allow to configure and memorized the instruments and all measurements remotely via web browser PC TABLET and SMARTPHONE Touch CONFIGURATION MENU from VOLUME screen Touch IP CONFIG and select DHCP IP...

Page 68: ...IP Example 192 168 15 134 index html 3 Insert in the USERNAME field the name of the instruments NAME preceded and followed with symbol_ Example _HD TAB 900_ 4 Insert in the PASSWORD field the Instrum...

Page 69: ...een Touch IP CONFIG and select STATIC insert the IP NMASK and GWAY parameters At the end touch EXIT to exit Touch METER and then LAN CONFIGURATION Touch CHECK NOTE for more information about the APP s...

Page 70: ...vitations to exhibitions and roadshows and much more besides UPDATE SW AREA REGISTRATION If you have not already registered click on the words Update SW in the menu in the top right hand corner of you...

Page 71: ...and turn it on 2 Wait for the Start Up phase of the Meter to finish correctly 3 Connect the USB cable first to the Meter and then to the PC 4 Start up the ROVER S M A R T program in your PC 5 In the R...

Page 72: ...finish correctly 3 Connect the USB cable first to the Meter and then to the PC 4 Make sure that you have installed the PRO Version and start up the ROVER S M A R T program in your PC 5 In the ROVER S...

Page 73: ...THE BATTERY ________________ WARNINGS IMPORTANT DO NOT LEAVE THE BATTERIES DISCHARGED FOR LONG PERIODS ALWAYS CHARGE THE BATTERIES AT NIGHT EVEN IF THEY ARE NOT COMPLETELY DISCHARGED USEFUL INFORMATI...

Page 74: ...d end amplifiers etc Extract the conditional access module cam if it is present in your meter 2 The battery test takes approx 12 18 Hours according to the model charging discharging recharging activit...

Page 75: ...iattiver automaticamente SPENTO SI ACCESO ACCESO Batterie in carica veloce SPENTO SI ACCESO SPENTO Carica batterie completata SPENTO CON ALIMENTATORE NON ORIGINALE ROVER Lampeggiante 0 5 SECONDI OFF 0...

Page 76: ...ratures over 60 C or 140 F Those temperatures can be easily reached when the meter is left in a car especially behind the windshield or in the trunk The LCD display and or other details may easily be...

Page 77: ...plastic chassis etc b Batteries 3 months from the date of purchase if original c Bags and carrying cases including shoulder straps 5 The equipment can not be replaced and the guarantee is extended aft...

Page 78: ...pecially regarding EMC and safety 10 ROVER Laboratories instruments is recognised and is fully compliant with DVB regulations and specifications ETS 300 421 12 94 and is consequently marked with the D...

Page 79: ...lay in the configuration menu If the meter does not switch on you can find the meter s serial number on the label placed on the back of the meter DETAILED and ACCURATE DESCRIPTION OF FAULT Please desc...

Page 80: ...e shows the suggested measurements at a user s socket for the main digital modulations DVB T2 GB COFDM PER 7 25 dB 28 dB 26 5 dB 29 5 dB 40 dB V 50 dB V 28 5 dB 31 5 dB MER 256 QAM 2 3 FEC MER 256 QAM...

Page 81: ...81 NOTE...

Page 82: ...2 0 cable for PC connection Battery charger power supply User guide hard copy User guide CD or USB F Female F Female connector BNC Female F Female connector IEC Female F Female connector QUICK F Male...

Page 83: ...Optional APPS 70 SERVICE SUPPORT web registration sw upgrades 70 S M A R T program 71 UPGRADE SOFTWARE procedure 72 MEMORY PLAN UPGRADES procedure 73 LI ION polimer BATTERIES 73 WARNINGS 74 BATTERY TE...

Page 84: ...A Via Parini 2 25019 Sirmione BS Italy tel 39 030 9198 1 fax 39 030 990 6894 Product specification are subject to change without notice All trademarks used are properties of their respective owners we...

Reviews: