8
Technical Specifications
General
Device type
RMS Data Logger
Measured parameters
Humidity & temperature with HygroClip HCD-S
Differencial pressure with PCD-S
CO2 with CCD-S
IP protection class
IP65
7
Range of application
-40..70 °C / 0..100 %RH
Storage and transport conditions
-40..30 °C / 0..90 %RH
Data memory
44,000 pairs of measured values
Interfaces
Ethernet (RMS-LOG-L)
Wireless 868 MHz (RMS-LOG-868)
Wireless 915 MHz (RMS-LOG-915)
Protocols
HTTP & MODBUS
Wireless range
20..50 m, indoors 868 MHz
15…25 m, indoors 915 MHz
Transmitting power
14dBm (25mW)
2dBm (1,6mW)
Software compatibility
≥V1.1
≥V1.2.1
General
Device type
RMS Display
IP protection class
IP65
8
Range of application
-20..30 °C / 0..100 %RH
Storage and transport conditions
-20..30 °C / 0..100 %RH
Interfaces
Ethernet (RMS-D-L)
Protocols
HTTP
Power Supply
Supply voltage
24 VDC ±10 % / <100 mA
9
PoE: 802.3af-2003, Class 1
7
IP65 protection is only fulfilled, when rubber plug is used for cabling.
8
IP65 protection is only fulfilled, when rubber plug is used for cabling.
9
Power supply requirements: 24 VDC ±10 % / >4 W / limited power source