background image

Operating Manual - 

EVO

®

 Line

[en] 07/2020

5.5

5.7 Air outlet

The pressure loss at the air outlet due to air after-

coolers, fittings, piping, etc.should be as small as 

possible.

Note:

Cross-sections of the outlet pipe must be gener-

ously dimensioned. Avoid pressure losses due to 

elbow screw fittings. 

The outlet pipe must be connected stress-free to 

the outlet.

Warning:

Serious injuries and damage are possible in case 

of operation without a safety valve!

Operation without a safety valve on the separator 

tank is not permitted.

Note:

A possible compressed air temperature (at the 

outlet) of up to 110°C/230°F requires the compo-

nents connected downstream, e.g. the com-

pressed-air hose, pressure switch, air after-cooler, 

fittings, etc. to be designed for this temperature.

We therefore recommend the installation of an air 

after-cooler.

When used without an air after-cooler, the high 

outlet temperature must be pointed out to the final 

customer.

5.8 Oil cooling

Note:

The cooler connection lines must be connected 

torque-free to the oil connections.

The following information on the design and exe-

cution of the oil cooling system must be observed.

– The oil cooling system must be designed so 

that the oil outlet temperature is a maximum of 

105°C/220°F at the maximum intended ambi-

ent temperature.

– The oil circulation quantity is dependent on the 

pressure difference between the outlet and the 

inlet pressure of your application.

– The oil cooler must be installed so that it can be 

cleaned easily.

– When designing the cooling system, the pres-

sure dew point graph (Figure 8-1) must be 

taken into account.

If questions arise concerning the pressure dew 

point, please contact ROTORCOMP.

5.9 Service

 

Ensure good accessibility to the service points 

when installing the screw compressor air end sys-

tem in a housing:

– Oil filling point

– Oil drain point

– Removal of the separator cartridge (removal 

dimensions according to offer drawing) 

– Removal of the oil filter cartridge (observe the 

removal dimensions specified in the offer draw-

ing) 

– Easy cleaning of the oil cooler

– Replacement of the shaft seal (removal and 

installation of the end cover and the bearing 

race)

– Belt drive (accessibility, specifications for cor-

rect belt tension)

Summary of Contents for EVO15

Page 1: ...ROTORCOMP VERDICHTER GmbH A Member of BAUER GROUP en 07 2020 SCREW COMPRESSOR AIR ENDS EVO2 EVO3 EVO3 G EVO6 EVO6 G EVO9 EVO9 G EVO15 EVO15 G EVO28 EVO28 G EVO42 EVO42 G OPERATING MANUAL...

Page 2: ...degree permitted by the applicable copyright laws is permitted without prior written approval The information contained in this document is subject to change without prior notice This document is not...

Page 3: ...Installation information 5 2 5 3 1 Drive 5 2 5 4 Belt drive 5 3 5 4 1 Belt tensioner with scale 5 3 5 5 Direct drive 5 4 5 5 1 Dimensions of centering flange 5 4 5 6 Air inlet 5 4 5 7 Air outlet 5 5...

Page 4: ...ROTORCOMP VERDICHTER Operating Manual EVO Line i 2 en 07 2020...

Page 5: ...completeness and possible damage Any missing parts and or trans port damage must be reported immediately A damaged screw compressor air end must not be put into operation under any circumstances Alway...

Page 6: ...r ends and components Optionally available components are marked with optional 1 6 Warranty information liability disclaimer ROTORCOMP is a manufacturer of screw com pressor components and not of read...

Page 7: ...or to make it available at the operating loca tion prior to installation and commissioning Prior to installation and commissioning the entire oper ating manual must be carefully read by the spe cially...

Page 8: ...e with doors open or shrouding loose Warning Hot machine parts Warning Pressurized part or system Lifting point Warning High voltage Active environmental protection Warning on a danger point Warning D...

Page 9: ...15 G EVO28 EVO28 G EVO42 and EVO42 G Figure 3 1 Screw compressor air end EVO9 1 Air inlet 2 Air outlet see installation drawing 3 Cover plate 4 Drive shaft 5 Nameplate 6 Oil injection 7 Direction of r...

Page 10: ...6 Oil injection 2 Air outlet see installation drawing 7 Direction of rotation 3 End cover 8 Oil return line non return valve not integrated 4 Drive shaft 9 Transmission 5 Nameplate 1 Air inlet 6 Oil...

Page 11: ...promptly for determination of damage i e A Damage or loss must be certified with a corresponding note on the freight bill before the merchandise is accepted With rail transports a record of the facts...

Page 12: ...ore lift ing the screw compressor air end Remove drive or body components before hand Only transport the compressor air ends while depressurized When transported on a pallet the compressor air end mus...

Page 13: ...contact surfaces should be machined and flat Only three of the holes 1 present in the housing support feed may be used for fastening The fourth hole 2 is to remain clear three point fastening 5 1 3 Pi...

Page 14: ...y dimensioned ground 5 3 Installation information Caution The system must be installed at a location at which the ambient air is as cool and clean as possible Never block the air inlet It must be ensu...

Page 15: ...c The V belt pulleys must be balanced It is not permissible to drive the belt pulley onto the drive shaft by striking it with a hammer and this can result in bearing damage When aligning the belt driv...

Page 16: ...The flanged unit must be fastened stress free on the base frame 5 5 1 Dimensions of centering flange Figure 5 4 Note The screws 1 8x must be replaced with longer screws when flanging on the transmissi...

Page 17: ...orque free to the oil connections The following information on the design and exe cution of the oil cooling system must be observed The oil cooling system must be designed so that the oil outlet tempe...

Page 18: ...ROTORCOMP VERDICHTER Operating Manual EVO Line 5 6 en 07 2020...

Page 19: ...eck the belt tension and belt routing see chapter 7 Maintenance Check the position of the shut off valve Check all screw fitting and fastening screws for firm seating Caution Commissioning is only all...

Page 20: ...to the air intake after removing the intake filter or manifold depending on the compressor size and the system Rotate the screw compressor air end again in the direction of rotation several times by h...

Page 21: ...ff from all pressure sources and a pressure relief of the entire sys tem must be carried out Never use flammable solvents or carbon tetra chloride to clean parts Take precautions against toxic vapors...

Page 22: ...after discharging As a result oil may escape when the oil filler plug is opened at the maximum oil level In this case close the oil filler plug again immediately and carefully remove the oil which has...

Page 23: ...Clean the oil drain screw and screw in again 7 3 3 Filling with oil Caution Observe the oil recommendation see Lubricants and Operating Materials Add oil of the same oil type and the same brand A con...

Page 24: ...k sheet Mark work carried out with an X or enter mea sured values and confirm with your signature Elapsed time meter reading Replace air intake filter Replace oil filter cartridge Replace oil fine sep...

Page 25: ...e sor module Maintenance intervals Bh operating hours Maintenance work Before commissioning Before start up check correct assembly of the screw compressor stage of drive elements and connections of co...

Page 26: ...ROTORCOMP VERDICHTER Operating Manual EVO Line 7 6 en 07 2020...

Page 27: ...oils 8 1 2 Topping up oil Use the same brand and the same oil type see adhesive label on the oil separating tank Dropping of the room temperature to below 5 C 23 F with the compressor stopped should b...

Page 28: ...r fan etc have been properly designed and the supply and exhaust air temperatures of the installation room and the screw compressor air end system make this possible The entire thermal economy must be...

Page 29: ...grade oil The use of multigrade oils can cause problems in the long run as viscosity improvers used are destroyed over time The oil is then no longer secured in the upper viscosity class and a thermal...

Page 30: ...ROTORCOMP VERDICHTER Operating Manual EVO Line 8 4 en 07 2020...

Page 31: ...or air end Model Drive outputs up to kW Volume flow up to m3 min Operating pressure up to bar Weight approx kg EVO2 11 2 15 15 EVO3 18 5 3 15 18 EVO3 G 18 5 3 15 34 EVO6 37 6 15 30 EVO6 G 37 6 15 70 E...

Page 32: ...orques must be used Always tighten screws bolts with a torque wrench Screw bolt type Thread Max torque Hexagonal head bolts Allen screws M 6 10 Nm 7 ft lbs Hexagonal head bolts Allen screws M 8 25 Nm...

Page 33: ...ed yet Check Oil filling too viscous Check viscosity 8 1 1 Differential pressure Pressure in the separator cartridge is too high if the cartridge is full or clogged Replace separator car tridge Combis...

Page 34: ...harged during continuous opera tion system does not switch off automatically in case of intermittent opera tion i e safety valve blows off Upper switching point of network pressure monitor set too hig...

Page 35: ...parts and replace if necessary System does not relieve Solenoid valve electrical system Check Impulse pressure relief valve Check and replace parts if necessary Control valve constantly discharges Sol...

Page 36: ...82110 Germering Germany Tel 49 0 89 724 09 0 Fax 49 0 89 724 09 38 info rotorcomp de www rotorcomp de 07 2020 Subject to change without notice INSTALLATION AND OPERATING MANUAL EVO CONTACT US WE ARE...

Reviews: