5.2 Eneo C / CC / CF with Phone & Code, power supply unit in general
1
1
2
2
3
3
4
4
5
5
6
6
Eneo C / CC / CF
GND
IN2
K1a
K1b
+24 V
IN1
Black
Green
Green
Green
Green
Yello
w
Gre
y
Pink
Green
Green
Bro
wn
Brown
Bro
wn
Bro
wn
Brown
Brown
Brown
Brown
Brown
W
hite
Yellow
Gre
y
Pink
W
hite
W
hite
White
White
White
White
White
White
Black Box
Access
control
system
Phone &
Code
Power
supply unit
IN:
100-230 V AC
OUT:
24 V DC
Video system
Push-button
Intercom
Inside
Outside
Outside:
“Unlock door”
access control system
JST plug connection
EZ cable,
3 m
Leaf side
Frame side
Plug-in
cable junction
Black
Black
Red
Red
+24 V
+24 V
GND
GND
230 V AC
Cable, 3 m
Potential-free contact
Potential-free contact
Signal (e.g. 12 V)
Inside:
“Unlock door” push-button,
optional for Eneo CC.
Phone & Code cable assignment
(between JST connector and Black Box)
White:
+24 V
Brown: GND
Green:
control (OPEN)
Connector / cable assignment
White:
IN1 / input 1 (OPEN)
Brown:
+24 V
Green: GND
Yellow:
IN2 / input 2
Grey:
K1a pot.-free contact
Pink:
K1b pot.-free contact
Switch
“Day / night”
Inside:
can be used
as an option.
INFO
The 24 V side
must not be wired.
INFO!
The yellow wire must remain
unassigned; otherwise this will
bridge the switch on the leaf.
Terminals 5 and 6 are connected
to one another internally via
a relay and a 47 ohm resistor.
The maximum load of the contacts
is 24 V / 40 mA
Connection diagram
Eneo C / CC / CF with Phone & Code, power supply unit in general
34 ·
05 / 2020
·
IMO_502_EN_v2
Roto Safe - Cable junctions
Subject to change.