GB
38
Image
The imager can display four different images.
The measurement spots cannot be displayed in combination with the digital zoom.
Emiss
Submenu Emiss - Emissivity
- Choose a factory set emissivity level from the comprehensive list of materials.
- Set specific emissivity Choose the submenu [Custom], set the required value with the
directional keys and save your selection.
Submenu T.Refl - Compensation of background radiation
- Select submenu.
- Set temperature value for background radiation. Generally it equals the ambient
temperature.
- Save settings.
Measurement
Up to three measuring points can be displayed on the imager.
Option
Description
Image
Spot
Central spot measurement
Whiter reticle and value S:
Max
Hotspot is displayed
Red reticle and value H:
Min
Coldspot is displayed
Blue reticle and value C:
Option
Description
IR
Displays a thermal image.
Visible
Display a natural image.
Fusion
Merges thermal and natural images. The merging ratio is adjustable in
four steps. Press the left or right buttons to adjust. - Default setting
AUF
Autofusion
In this image mode the imager generates a mix of natural and thermal
image dynamically. Automatic and manual Autofusion are available.
Automatic Autofusion boosts the recognition value of thermal images
at low temperature differences. Manual Autofusion highlights selected
temperatures inside the measured area.