x
Hydraulic system integration
52
FA ROTEX Solaris RPS3 25M - 03/2010
Table 7-1 Short names in hydraulic drawings
7.3
Connection of a pressurised collector system
If the building situation makes it impossible to
mount the solar panels above the hot water storage tanks or if the connection
pipe cannot be installed with a continuous gradient between the collector array and the hot water storage tanks,the
unpressu-
rised ROTEX Solaris system (DrainBack) and thus
the Control unit RPS3 25M cannot be used
.
Instead, the heating installation can be implemented with the ROTEX Solaris pressurised system. The following Solaris compo-
nents can be used equally in both systems:
•
Solaris high output flat panel collectors V21P, V26P, H26P
•
Solaris on-roof, flat roof and in-roof mounting packages
•
Solaris hot water storage tanks
Other system components may only be used on a system by system basis.
RKHB
Inside unit for HPSU Bi-Bloc heat pump
Supplied with HPSU heat pump.
RRHQ
Outside unit for HPSU Bi-Bloc heat pump
RT
Room thermostat
Accessories
14 10 03
SK
Solaris high-efficiency flat solar panel
Solaris V21P
16 20 12
Solaris V26P
16 20 10
Solaris H26P
16 20 11
SV
Safety pressure relief valve
on site
T
R
Solaris return temperature sensor
Supplied with RPS3.
T
S
Solaris storage tank temperature sensor
Supplied with RPS3.
T
V
Solaris flow temperature sensor
Supplied with FLS.
T
K
Solaris collector temperature sensor
Supplied with roof penetration kit.
t
DHW
Storage tank temperature sensor
Supplied with GSU/connecting set A1, HPSU.
t
Mi
Mixer circuit flow temperature sensor
Accessories
15 60 62
t
V
Heating inflow temperature probe
Supplied with GSU/A1-Inline.
t
R
Heating return temperature sensor
t
AG
Flue gas temperature sensor
Accessories
15 70 52
t
AU
Outside temperature sensor
Supplied with GSU/A1-Inline, HPSU.
VS
Scalding protection VTA 32
Accessories
15 60 15
Short name
Meaning
Remark
Order No.