3
x
Set-up and installation
17
FA ROTEX SC+HYC - 10/2009
3.3
Installation
3.3.1
Overview of connections
Sanicube (SC) / Sanicube Solaris (SCS)
HybridCube (HYC)
1
Solaris - flow (1“ union nut) (SCS only)
2
Cold water supply (1“ male
)*
3
Hot water (1“ male
)*
4
Tank charge feed (SC - "heating 1“; SCS - "heating 2“) (1“ AG)*
5
Tank charge return flow (SC - "heating 1“; SCS - "heating 2“) (1“ AG)*
6
Tank charge feed (2nd heat source - "heating 3“) (1“ AG)*
7
Tank charge return flow (2nd heat source - "heating 3“) (1“ AG)*
8
Solar support to heating system flow (SCS 538/xx/xx only) (1“ male)*
(Connect to heating return to boiler!)
9
Solar support to heating system return (SCS 538/xx/xx only) (1“ male)*
(Connect to heating return from system!)
10
Storage tank (double-walled jacket made of polypropylene with PUR
hard foam thermal insulation)
11
Filling and drain connection (Tr. 32
x3 male) with valve insert (SCS: Solaris return flow)
12
Connection for equalising pipe (AGL,
16 01 08) or extension set for
another heat source (EWS,
16 01 10)
18
Connection for electric immersion heater element (R 11/2“ female)
20
Filling level indicator
22
Sensor immersion sleeve for storage tank temperature sensor
26
Type plate
27
Safety overflow connection (Tr. 32x3 male)
28
Handle
*
Recommended accessories (non return valves (2 pcs),
16 50 70)
Fig. 3-8
External connections (shown on Sanicube SCS)
1
Solaris - flow (1“ swivel nut)
2
Cold water supply (1“ male
)*
3
Hot water (1“ male
)*
4
Tank charge flow (1“ male)*
5
Tank charge return flow (1“ swivel nut)*
6
Heating support return flow (1“ ÜM)* only HYC 544
7
Heating support return flow (1“ AG)* only HYC 544
10
Storage tank (double-walled jacket made of polypropylene with PUR
hard foam thermal insulation)
11
Filling and drain connection (Tr. 32
x3 male) with valve insert (Solaris return flow)
12
Connection for equalising line (AGL,
16 01 08)
18
Solaris flow multilayer pipe
19
Filling level indicator
20
Booster Heater (EHS)
21
Dip sensor sleeve for tank temperature sensor
25
Type plate
26
Safety overflow connection (Tr. 32x3 male)
27
Handle
*
Recommended accessories (non return valves (2 pcs),
16 50 70)
Fig. 3-9
External connections (shown on HYC 544*)
1
2
4
5
6
7
3
8
9 18
22
26
27
20
10
28
12
11